Multi-function analog inputs (h3-05, h3-09), Monitor function – Yaskawa G7 Drive User Manual

Page 339

Advertising
background image

6

-122

* Factory setting will change according to the control mode (factory settings for Flux Vector Control are shown here).

Multi-function Contact Input Functions (H1-01 to H1-10)

Multi-function Contact Output Functions (H2-01 to H2-05)

Multi-function Analog Inputs (H3-05, H3-09)

Monitor Function

H3-10

Terminal A2
Gain Setting

Sets the output level when 10V is
input.

0.0

to

1000.0

100.0%

Yes

A

A

A

A

A

Terminal A2
Gain

H3-11

Terminal A2
Bias Setting

Sets the output level when 0V is
input.

-100.0

to

+100.0

0.0%

Yes

A

A

A

A

A

Terminal A2
Bias

Setting

Value

Function

Control Methods

V/f

V/f

with

PG

Open

Loop

Vector

1

Flux

Vector

Open

Loop

Vector

2

71

Speed/torque control change (ON: Torque control)

No

No

No

Yes

Yes

78

Polarity reverse command for external torque reference

No

No

No

Yes

Yes

Setting

Value

Function

Control Methods

V/f

V/f

with

PG

Open

Loop

Vector

1

Flux

Vector

Open

Loop

Vector

2

32

Speed control circuit operating for torque control (except when stopped).
The external torque reference will be limited if torque control is selected.
Output when the motor is rotating at the speed limit.

No

No

No

Yes

Yes

Setting

Value

Function

Control Methods

V/f

V/f

with

PG

Open

Loop

Vector

1

Flux

Vector

Open

Loop

Vector

2

0

Add to terminal A1

Yes

Yes

Yes

Yes

Yes

13

Torque reference/torque limit at speed control

No

No

No

Yes

Yes

14

Torque compensation

No

No

No

Yes

Yes

Parameter

Number

Name

Description

Output Signal Level During

Multi-Function Analog Output

Min.

Unit

Control Methods

Display

V/f

V/f

with

PG

Open

Loop

Vector

1

Flux

Vector

Open

Loop

Vector

2

U1-09

Torque refer-
ence

Monitor in internal torque
reference value for vector
control.

10 V: Motor rated torque

(0 to ± 10V possible)

0.1%

No

No

A

A

A

Torque Refer-
ence

Parameter

Number

Name

Description

Setting
Range

Factory

Setting

Change

during

Operation

Control Methods

Display

V/f

V/f

with

PG

Open

Loop

Vector

1

Flux

Vector

Open

Loop

Vector

2