Multi-function contact output functions – Yaskawa G7 Drive User Manual

Page 165

Advertising
background image

5

-54

Multi-function Contact Output Functions

Setting

Value

Function

Control Methods

V/f

V/f

with

PG

Open

Loop

Vector

1

Flux

Vector

Open

Loop

Vector

2

0

During run (ON: run command is ON or voltage is being output)

Yes

Yes

Yes

Yes

Yes

1

Zero-speed

Yes

Yes

Yes

Yes

Yes

2

Frequency agree 1 (L4-02 used.)

Yes

Yes

Yes

Yes

Yes

3

Desired frequency agree 1 (ON: Output frequency = ±L4-01, L4-02 used and
during frequency agree)

Yes

Yes

Yes

Yes

Yes

4

Frequency (FOUT) detection 1 (ON: +L4-01

≥ output frequency ≥ -L4-01, L4-02

used)

Yes

Yes

Yes

Yes

Yes

5

Frequency (FOUT) detection 2 (ON: Output frequency

≥ +L4-01 or output

frequency

≤ -L4-01, L4-02 used)

Yes

Yes

Yes

Yes

Yes

6

Drive operation ready
READY: After initialization, no faults

Yes

Yes

Yes

Yes

Yes

7

During DC bus undervoltage (UV) detection

Yes

Yes

Yes

Yes

Yes

8

During baseblock (ON: during baseblock)

Yes

Yes

Yes

Yes

Yes

9

Frequency reference selection (ON: Frequency reference from Operator)

Yes

Yes

Yes

Yes

Yes

A

Run command selection status (ON: Run command from Operator)

Yes

Yes

Yes

Yes

Yes

B

Overtorque/undertorque detection 1 NO (NO contact: Overtorque/undertorque
detection at ON)

Yes

Yes

Yes

Yes

Yes

C

Loss of frequency reference (Effective when 1 is set for L4-05)

Yes

Yes

Yes

Yes

Yes

D

Braking resistor fault (ON: Resistor overheat or braking transistor fault)

Yes

Yes

Yes

Yes

Yes

E

Fault (ON: Digital Operator communications error or fault other than CPF00 and
CPF01 has occurred.)

Yes

Yes

Yes

Yes

Yes

F

Not used. (Set when the terminals are not used.)

-

-

-

-

-

10

Minor fault (ON: Alarm displayed)

Yes

Yes

Yes

Yes

Yes

11

Fault reset command active

Yes

Yes

Yes

Yes

Yes

12

Timer function output

Yes

Yes

Yes

Yes

Yes

13

Frequency agree 2 (L4-04 used)

Yes

Yes

Yes

Yes

Yes

14

Desired frequency agree 2 (ON: Output frequency = L4-03, L4-04 used, and
during frequency agree)

Yes

Yes

Yes

Yes

Yes

15

Frequency detection 3 (ON: Output frequency

≤ -L4-03, L4-04 used)

Yes

Yes

Yes

Yes

Yes

16

Frequency detection 4 (ON: Output frequency

≥ -L4-03, L4-04 used)

Yes

Yes

Yes

Yes

Yes

17

Overtorque/undertorque detection 1 NC (NC Contact: Torque detection at OFF)

Yes

Yes

Yes

Yes

Yes

18

Overtorque/undertorque detection 2 NO (NO Contact: Torque detection at ON)

Yes

Yes

Yes

Yes

Yes

19

Overtorque/undertorque detection 2 NC (NC Contact: Torque detection at OFF)

Yes

Yes

Yes

Yes

Yes

1A

During reverse run (ON: During reverse run)

Yes

Yes

Yes

Yes

Yes

1B

During baseblock 2 (OFF: During baseblock)

Yes

Yes

Yes

Yes

Yes

1C

Motor selection (Motor 2 selected)

Yes

Yes

Yes

Yes

Yes

1D

During regenerative operation (ON: During regenerative operation)

No

No

No

Yes

Yes

1E

Restart enabled (ON: Restart enabled)

Yes

Yes

Yes

Yes

Yes

1F

Restart enabled (ON: Restart enabled)

Yes

Yes

Yes

Yes

Yes