Analog reference card: f2 – Yaskawa G7 Drive User Manual

Page 155

Advertising
background image

5

-44

„

Analog Reference Card: F2

User parameters for the Analog Reference Card are shown in the following table.

Parameter

Number

Name

Description

Setting

Range

Factory

Setting

Change

during

Operation

Control Methods

MODBUS

Register

Display

V/f

V/f

with

PG

Open

Loop

Vector

1

Flux

Vector

Open

Loop

Vector

2

F1-23

PG Gear Teeth
Count 1

Sets the number of gear teeth
(deceleration ratio) between
Motor-2 and the pulse generator.

[(RPMs x 60)/PGpulseCount]
x (F1-24)/(F1-23)

If either value is zero, then
the decleration ratio will
equal "1".

0

to

1000

0

No

No

A

No

No

No

3B2H

PG Gear
Teeth1

F1-24

PG Gear Teeth
Count 2

0

to

1000

0

No

No

A

No

No

No

3B3H

PGO Gear
Teeth2

F1-25

Hardware
Disconnected
Detection
Selection CH1

Enables or disables the drive
from detecting when the PG
option on CH1 has been
disconnected.
0: Disabled.
1: Enabled.
When using PG-T2 or Z2,
this setting is enabled.

0 to 1

1

No

No

A

No

A

No

3B4H

HW PGO ch1

F1-26

Hardware
Disconnected
Detection
Selection CH2

0 to 1

1

No

No

A

No

A

No

3B5H

HW PGO ch2

Parameter

Number

Name

Description

Setting

Range

Factory

Setting

Change

during

Operation

Control Methods

MODBUS

Register

Display

V/f

V/f

with

PG

Open

Loop

Vector

1

Flux

Vector

2

F2-01

AI-14 Input
Selection

Sets the function for channel
1 to 3 of the AI-14B analog
input reference option board.

0: 3-channel individual

(Channel 1: terminal A1,
Channel 2: terminal A2,
Channel 3: terminal A3)

1: 3-channel addition

(Summed values of
channels 1 to 3 is the
frequency reference)

When set to 0, select 1 for
b1-01. In this case, the
multi-function input "Option/
Inverter selection" cannot be
used.

0 or 1

0

No

A

A

A

A

A

38FH

AI-14 Input
Sel

Advertising