User parameter descriptions, Description of user parameter tables – Yaskawa G7 Drive User Manual

Page 113

Advertising
background image

5

-2

User Parameter Descriptions

This section describes the contents of the user parameter tables.

‹

Description of User Parameter Tables

User parameter tables are structured as shown below. Here, b1-01 (Frequency Reference Selection) is used as
an example.

Parameter

Number

Name

Description

Setting

Range

Factory

Setting

Change

during

Opera-

tion

Control Methods

MODBUS

Register

V/f

V/f

with

PG

Open

-loop

Vec-

tor

1

Flux

Vec-

tor

Open

Loop

Vec-

tor

2

Display

b1-01

Reference
selection

Selects the frequency
reference input source.
0: Operator - Digital preset

speed U1-01 or d1-01 to
d1-17.

1: Terminals - Analog input

terminal A1 (or terminal
A2 based on parameter
H3-09).

2: Serial Com - Modbus RS-

422/485 terminals R+, R-,
S+, and S-.

3: Option PCB - Option board

connected on 2CN.

4: Pulse Input (Terminal RP)

0 to 4

1

No

Q

Q

Q

Q

Q

180H

Reference
Source

• Parameter Number:

The number of the user parameter.

• Parameter Name:

The name of the user parameter.

• Description:

Details on the function or settings of the user parameter.

• Setting Range:

The setting range for the user parameter.

• Factory Setting:

The factory setting (each control method has its own factory setting.
Therefore the factory setting changes when the control method is
changed.)
Refer to page 5-96 for factory settings by control method.

• Change during Operation:

Indicates whether or not the parameter can be changed while the
Drive is in operation.
Yes: Changes possible during operation.
No: Changes not possible during operation.

• Control Methods:

Indicates the control methods in which the user parameter can be
monitored or set.
Q:

Items which can be monitored and set in either quick program-
ming mode or advanced programming mode.

A:

Items which can be monitored and set only in advanced pro-
gramming mode.

No: Items which cannot be monitored or set for the control method.

• MODBUS Address:

The register number used for MODBUS communications.

• Page:

Reference page for more detailed information on the parameter.

Advertising