Specifications of Options and Peripheral Devices

9-

7

Built-in

(con-

nect to

con-

nector)

PG

Speed

Con-

trol

Cards

PG-A2

73600-

A012X

Used for V/f with PG control. Speed feedback is performed
using the PG attached to the motor to compensate for speed
fluctuations caused by slipping.
• A-phase pulse (single pulse) input (voltage, complemen-

tary, open-collector input)

• Maximum input frequency: 32767 Hz
• Pulse monitor output: +12 V, 20 mA
(PG power supply output: +12 V, 200 mA max.)

-

PG-B2

73600-

A013X

• Used for V/f control.
• A-, B-phase input (complimentary input)
• Maximum input frequency: 32767 Hz
• Pulse monitor output: Open-collector
(PG power supply output: +12 V, 200 mA max.)

-

PG-D2

73600-

A014X

• Differential input.
• A-phase pulse (differential pulse) input, for V/f control
• Maximum input frequency: 300 kHz
• Input: Conforms to RS-422
• Pulse monitor output: RS-422
(PG power supply output: +5 or +12 V, 200 mA max.)

-

PG-X2

73600-

A015X

• A-, B-, Z-phase pulse (differential pulse) input
• Maximum input frequency: 300 kHz
• Input: Conforms to RS-422
• Pulse monitor output: RS-422

(PG power supply output: +5 or +12 V, 200 mA max.)

-

Table 9.5 Option Cards (Continued)

Type

Name

Code

Number

Function

Document

Number