6

-162

„

Application Precautions

The DI-08 will not function if F3-01 is set to 6

„

Selecting the Digital Reference

The range of the digital references is determined by the combination of the settings of o1-03 and F3-01. The
information monitored in U1-01 (Frequency reference) will also change.

DI-16H2 Reference Ranges

When using the DI-16H2, the following ranges can be set depending on the settings of the parameters.

Terminal

Pin No.

8-bit Binary with Sign

2-digit BCD with Sign

F3-01 = 7

F3-01 = 0 to 5

TC

1

Bit 1 (2

0

)

1

BDC digit 1

(0 to 9)

2

Bit 1 (2

1

)

2

3

Bit 1 (2

2

)

4

4

Bit 1 (2

3

)

8

5

Bit 1 (2

4

)

1

BDC digit 2

(0 to 15)

6

Bit 1 (2

5

)

2

7

Bit 1 (2

6

)

4

8

Bit 1 (2

7

)

8

9

Sign signal

10

SET (read) signal

11

Reference common signal (0 V)