6

-38

‹

Stabilizing Speed (Speed Feedback Detection Function)

The speed feedback detection control (AFR) function measures the stability of the speed when a load is sud-
denly applied, by calculating the amount of fluctuation of the torque current feedback value, and compensat-
ing the output frequency with the amount of fluctuation.

„

Related Parameters

Parameter

Number

Name

Description

Setting
Range

Factory

Setting

Change

during

Operation

Control Methods

Display

V/f

V/f

with

PG

Open

Loop

Vector

1

Flux

Vector

Open

Loop

Vector

2

n2-01

Speed
Feedback
Detection
Control (AFR)
Gain

Sets the internal speed feedback
detection control gain in the
automatic frequency regulator
(AFR).
Normally, there is no need to
change this setting. Adjust this
parameter as follows:

- If hunting occurs, increase the

set value.

- If response is low, decrease

the set value.

Adjust the setting by 0.05 units

at a time, while checking the
response.

0.00

to

10.00

1.00

No

No

No

A

No

No

AFR Gain

n2-02

Speed
Feedback
Detection
Control (AFR)
Time Constant

Sets the time constant to control
the rate of change in the speed
feedback detection control.

0

to

2000

50ms

No

No

No

A

No

No

AFR Time