Yaskawa G7 Drive User Manual

Page 387

Advertising
background image

7

-6

FBL

Feedback

Loss

PID Feedback Reference Lost
A PID feedback reference loss was
detected (b5-12 = 2) and the PID feed-
back input was less than b5-13 (PID
feedback loss detection level) for
longer than the time set in b5-14 (PID
feedback loss detection time).

-

-

EF0

Opt Exter-

nal Flt

External fault input from Communi-
cations Option Card

-

Check the Communications
Option Card and communications
signals.

EF3

Ext Fault

S3

External fault (Input terminal 3)

An “external fault” was input from a
multi-function input terminal.

• Reset external fault inputs to the

multi-function inputs.

• Remove the cause of the exter-

nal fault.

EF4

Ext Fault

S4

External fault (Input terminal 4)

EF5

Ext Fault

S5

External fault (Input terminal 5)

EF6

Ext Fault

S6

External fault (Input terminal 6)

EF7

Ext Fault

S7

External fault (Input terminal 7)

EF8

Ext Fault

S8

External fault (Input terminal 8)

EF9

Ext Fault

S9

External fault (Input terminal 9)

EF10

Ext Fault

S10

External fault (Input terminal 10)

EF11

Ext Fault

S11

External fault (Input terminal 11)

EF12

Ext Fault

S12

External fault (Input terminal 12)

SVE

Zero Servo

Fault

Zero Servo Fault
The rotation position moved during
zero servo operation.

The torque limit is too small.

Increase the limit.

The load torque is too large.

Reduce the load torque.

-

Check for signal noise.

Table 7.1 Fault Displays and Processing (Continued)

Display

Meaning

Probable Causes

Corrective Actions

Advertising