User Parameter Tables

5-

91

U1-44

ASR
Output
without
Filter

Output from the speed control
loop (ASR) before the ASR
primary delay filter (C5-06).
100% is displayed for rated
secondary current of the
motor.

10V: Motor Rated Secondary
Current
(0V to ±10V)

0.0

1%

No

No

No

A

A

6BH

ASR
Output w
Fil

U1-45

Feed
Forward
Control
Output

Output from feed forward
control. 100% is displayed for
rated secondary current of the
motor.

10V: Motor Rated Secondary
Current
(0V to ±10V)

0.0

1%

No

No

No

A

A

6CH

FF Cout
Output

U1-50

CF Fault
Error Code

Displays the code for a CF

fault:

00: No deceleration for 3sec

after reaching the stop
frequency.

01: Flux estimation fault.
02: Start status error.
04: Observer gain adjustment

error.

08: Regeneration error at low

speeds.

10: Zero Speed error.
20: Rotational Direction Limit

error.

80: Vector control status error

Setting Range
(0 thru FFFFFH)

-

No

No

No

No

A

71H

CF Error
Code

Parameter

Number

Name

Description

Output Signal Level

During Multi-Function

Analog Output

Min.

Unit

Control Methods

MODBUS

Register

Display

V/f

V/f

with

PG

Open

Loop

Vector

1

Flux

Vector

Open

Loop

Vector

2