Motor setup: e2 – Yaskawa G7 Drive User Manual

Page 147

Advertising
background image

5

-36

* 2. The factory setting will change when the control method is changed. (Open-loop vector 1 factory settings are given.)
* 3. E1-11 and E1-12 are disregarded when set to 0.0.
* 4. E1-13 is set to the same value as E1-05 by Autotuning.
* 5. Setting range changes to 0 thru 66.0 when operating in Vector 2 wo/PG . The upper limit for the setting range also depends on the upper limit in E1-04.

„

Motor Setup: E2

E1-13

Base
Voltage

Set only when the V/F pattern is
finely adjusted in the constant
power (HP) area above base speed.
Adjustment is not normally
required.If E1-13 = 0.0, then value
in E1-05 is used for E1-13.
Auto-Tuning sets this value.

0.0

to

255.0

(240V)

0.0

to

510.0

(480V)

0.0

Vac

*4

No

A

A

Q

Q

Q

30CH

Base
Voltage

Parameter

Number

Name

Description

Setting

Range

Factory

Setting

Change

during

Operation

Control Methods

MODBUS

Register

Display

V/f

V/f

with

PG

Open

Loop

Vector

1

Flux

Vector

Open

Loop

Vector

2

E2-01

Motor Rated
current

Sets the motor nameplate full
load current in amperes (A).
This value is automatically
set during Auto-Tuning.

0.32

to

6.40

*2

1.90 A

*1

No

Q

Q

Q

Q

Q

30EH

Motor Rated
FLA

E2-02

Motor Rated
Slip

Sets the motor rated slip in
hertz (Hz). This value is
automatically set during
rotational Auto-Tuning.

0.00

to

20.00

2.90Hz

*1

No

A

A

A

A

A

30FH

Motor Rated
Slip

E2-03

Motor No-
load Current

Sets the magnetizing current
of the motor as a percentage
of full load amps (E2-01).
This value is automatically
set during rotational Auto-
Tuning.

0.00

to

1.89

*3

1.20 A

*1

No

A

A

A

A

A

310H

No-Load
Current

E2-04

Number of
Motor Poles

Sets the number of motor
poles.
This value is automatically
set during Auto-Tuning.

2 to 48 4 poles

No

No

Q

No

Q

Q

311H

Number of
Poles

E2-05

Motor
Line-to-line
Resistance

Sets the phase-to-phase motor
resistance in ohms.
This value is automatically
set by Auto-Tuning.

0.000

to

65.000

9.842

Ω

*1

No

A

A

A

A

A

312H

Term
Resistance

E2-06

Motor Leak
Inductance

Sets the voltage drop due to
motor leakage inductance as a
percentage of the motor rated
voltage.
This parameter is automatically
set during Auto-Tuning.

0.0

to

40.0

18.2%

*1

No

No

No

A

A

A

313H

Leak
Inductance

E2-07

Motor
Iron-core
Saturation
Coefficient 1

Sets the motor iron saturation
coefficient at 50% of
magnetic flux.
This value is automatically
set during rotational
Auto-Tuning.

0.00

to

0.50

0.50

No

No

No

A

A

A

314H

Saturation
Comp1

E2-08

Motor
Iron-core
Saturation
Coefficient 2

Sets the motor iron saturation
coefficient at 75% of
magnetic flux.
This value is automatically
set during rotational
Auto-Tuning.

0.5

to

0.75

0.75

No

No

No

A

A

A

315H

Saturation
Comp2

Parameter

Number

Name

Description

Setting

Range

Factory

Setting

Change

during

Operation

Control Methods

MODBUS

Register

Display

V/f

V/f

with

PG

Open

Loop

Vector

1

Flux

Vector

Open

Loop

Vector

2