User Parameter Tables

5-

57

H3-05,H3-09 Settings

Setting

Value

Function

Contents (100%)

Control Methods

V/f

V/f

with

PG

Open

Loop

Vector

1

Flux

Vector

Open

Loop

Vector

2

0

Frequency Bias

100% = Maximum output frequency (E1-04)

Yes

Yes

Yes

Yes

Yes

1

Frequency Reference Gain
(FGAIN)

100% = Frequency reference command value A1
Total gain = Internal gain (H3-02) x FGAIN

Yes

Yes

Yes

Yes

Yes

2

Aux Frequency Reference 1

Used in conjunction with multi-function inputs
"multi-step frequency reference 1-4" (d1-16).
100% = Maximum output frequency (E1-04)

Yes

Yes

Yes

Yes

Yes

3

Aux Frequency Reference 2

Used in conjunction with multi-function inputs
"multi-step frequency reference 1-4" (d1-16).
100% = Maximum output frequency (E1-04)

Yes

Yes

Yes

Yes

Yes

4

Output Voltage Bias

100% = Motor rated voltage (E1-05).
Voltage boost after V/F pattern

Yes

Yes

No

No

No

5

Accel / Decel Time Coefficient

100% = Active accel / decel time (C1-01 thru C1-08)

Yes

Yes

Yes

Yes

Yes

6

DC Injection Braking Current

100% = Drive rated current.
Parameter b2-02 is disabled.

Yes

Yes

Yes

No

No

7

Overtorque / Undertorque
Detection Level

Used for multi-function digital output for
"overtorque/undertorque".
100% = motor rated torque (OLV, FV) or Drive rated
current (V/F, V/F w/PG).
Internal overtorque detection level (C6-02) disabled.

Yes

Yes

Yes

Yes

Yes

8

Stall Prevention Level During Run 100% = L3-06.

Yes

Yes

No

No

No

9

Frequency Reference Lower Limit

100% = Maximum output frequency (E1-04).
Either the setting in d2-02 or the A3 input level is
enabled, whichever is larger.

Yes

Yes

Yes

Yes

Yes

A

Jump Frequency

100% = Maximum output frequency (E1-04).

Yes

Yes

Yes

Yes

Yes

B

PID Feedback

100% = Maximum output frequency (E1-04).

Yes

Yes

Yes

Yes

Yes

C

PID Set Point

100% = Maximum output frequency (E1-04).
Frequency reference no longer acts as a PID setpoint.

Yes

Yes

Yes

Yes

Yes

D

Frequency Reference Bias 2

100% = Maximum output frequency
(E1-04).
Total bias = Internal bias (H3-03) + FBIAS (H3-07) +
A3 input level

Yes

Yes

Yes

Yes

Yes

E

Motor Temperature Input

10V = 100%
See parameters L1-03 and L1-04

Yes

Yes

Yes

Yes

Yes

10

FWD Torque Limit (Quadrant 1)

100% = Motor rated torque.

No

No

Yes

Yes

Yes

11

REV Torque Limit (Quadrant 3)

100% = Motor rated torque.

No

No

Yes

Yes

Yes

12

Regenerative Torque Limit (Quad-
rants 2 and 4)

100% = Motor rated torque.

No

No

Yes

Yes

Yes

13

Torque Reference (in Torque Con-
trol); Torque Limit (in Speed Con-
trol)

100% = Motor rated torque.

No

No

No

Yes

Yes

14

Torque Compensation

100% = Motor rated torque.

No

No

No

Yes

Yes

15

FWD / REV Torque Limit

100% = Motor rated torque.

No

No

Yes

Yes

Yes

1F

Analog input not used.

-

Yes

Yes

Yes

Yes

Yes

16 to 1E

Not used

-

-

-

-

-

-