-148

An error may occur during the comparison. If an error is displayed, press any key to cancel the error display
and return to the o3-01 display. Error displays and their meanings are shown below. (Refer to Chapter 7
Errors when Using Digital Operator Copy Function.)

„

Application Precautions

When using the copy function, check that the following settings are the same between the Drive and the Digi-
tal Operator.

‹

Prohibiting Writing Parameters from the Digital Operator

If you set A1-01 to 0, you can refer to and set the A1 and A2 parameter groups, and refer to drive mode, using
the Digital Operator.

If you set one of the parameters H1-01 to H1-05 (multi-function contact input terminal S3 to S7 function
selection) to 1B (write parameters permitted), you can write parameters from the digital operator when the ter-
minal that has been set is ON. When the set terminal is OFF, writing parameters other than the frequency ref-
erence is prohibited. You can, however, reference parameters.

Error Display

Meaning

Verify error (Settings in the Digital Operator and the Drive do not match).

Drive product and type

Drive capacity and voltage

Software number

Control method

Parameter

Number

Name

Description

Setting
Range

Factory

Setting

Change

during

Operation

Control Methods

Display

V/f

V/f

with

PG

Open

Loop

Vector

1

Flux

Vector

Open

Loop

Vector

2

A1-01

Access Level
Selection

Selects which parameters are

accessible via the Digital
Operator.

0: Operation Only
1: User Level (only available if

A2 parameters have been set)

2: Advanced Level

0 to 2

2

Yes

A

A

A

A

A

Access Level

VYE