Yaskawa G7 Drive User Manual

Page 140

Advertising
background image

User Parameter Tables

5-

29

Note The unit is set in o1-03 (frequency units of reference setting and monitor). The default for o1-03 is 0 (increments of 0.01Hz).
* Setting range changes to 0 thru 66.0 when operating in Vector 2 wo/PG. The upper limit for the setting range also depends on the upper limit in E1-04. The

max setting is 400.00.

d1-10

Frequency
Reference 10

Frequency reference when
multi-function input
"Multi-step speed reference 1, 4"
is ON. Setting units are
affected by o1-03.

0

to

400.00

*

0.00Hz

Yes

A

A

A

A

A

28BH

Reference 10

d1-11

Frequency
Reference 11

Frequency reference when
multi-function input
"Multi-step speed reference 2, 4"
is ON. Setting units are
affected by o1-03.

0.00Hz

Yes

A

A

A

A

A

28CH

Reference 11

d1-12

Frequency
Reference 12

Frequency reference when
multi-function input
"Multi-step speed reference 1, 2, 4"
is ON. Setting units are
affected by o1-03.

0.00Hz

Yes

A

A

A

A

A

28DH

Reference 12

d1-13

Frequency
Reference 13

Frequency reference when
multi-function input
"Multi-step speed reference 3, 4"
is ON. Setting units are
affected by o1-03.

0.00Hz

Yes

A

A

A

A

A

28EH

Reference 13

d1-14

Frequency
Reference 14

Frequency reference when
multi-function input
"Multi-step speed reference 1, 3, 4"
is ON. Setting units are
affected by o1-03.

0.00Hz

Yes

A

A

A

A

A

28FH

Reference 14

d1-15

Frequency
Reference 15

Frequency reference when
multi-function input
"Multi-step speed reference 2, 3, 4"
is ON. Setting units are
affected by o1-03.

0.00Hz

Yes

A

A

A

A

A

290H

Reference 15

d1-16

Frequency
Reference 16

Frequency reference when
multi-function input
"Multi-step speed reference 1, 2, 3, 4"
is ON. Setting units are
affected by o1-03.

0.00Hz

Yes

A

A

A

A

A

291H

Reference 16

d1-17

Jog
Frequency
Reference

Frequency reference when:
"Jog frequency reference" is
selected via multi-function
input terminals. "Jog
frequency reference" has
priority over "multi-step
speed reference 1 to 4".
Parameter d1-17 is also the
reference for the JOG key on
the Digital Operator, and the
multi-function inputs
"forward jog" and "reverse
jog". Setting units are
affected by o1-03.

6.00Hz

Yes

Q

Q

Q

Q

Q

292H

Jog
Reference

Parameter

Number

Name

Description

Setting

Range

Factory

Setting

Change

during

Operation

Control Methods

MODBUS

Register

Display

V/f

V/f

with

PG

Open

Loop

Vector

1

Flux

Vector

Open

Loop

Vector

2