Yaskawa G7 Drive User Manual

Page 180

Advertising
background image

User Parameter Tables

5-

69

L6-02

Torque
Detection
Level 1

Sets the Overtorque/
Undertorque detection level as
a percentage of Drive rated
current or torque for Torque
Detection 1. Current detection
for A1-02 = 0 or 1. Torque
detection for A1-02 = 2 or 3.

0

to

300

150%

No

A

A

A

A

A

4A2H

Torq Det 1
Lvl

L6-03

Torque
detection
time 1

Sets the length of time an
Overtorque/Undertorque
condition must exist before
Torque Detection 1 is
recognized by the Drive.

0.0

to

10.0

0.1sec

No

A

A

A

A

A

4A3H

Torq Det 1
Time

Parameter

Number

Name

Description

Setting

Range

Factory

Setting

Change

during

Operation

Control Methods

MODBUS

Register

Display

V/f

V/f

with

PG

Open

Loop

Vector

1

Flux

Vector

Open

Loop

Vector

2