Advanced programming mode, Advanced programming mode -10, Example operations – Yaskawa G7 Drive User Manual

Page 83: Fig 3.4 operations in advanced programming mode

Advertising
background image

3

-10

‹

Advanced Programming Mode

In advanced programming mode, all Drive parameters can be monitored and set.

Parameters can be changed from the setting displays. Use the Increment, Decrement, and Shift/RESET Keys
to change the frequency. The user parameter will be written and the monitor display will be returned to when
the DATA/ENTER Key is pressed after changing the setting.

Refer to Chapter 5 User Parameters for details on the parameters.

„

Example Operations

Key operations in advanced programming mode are shown in the following figure.

Fig 3.4 Operations in Advanced Programming Mode

A1- 00=

0

** Main Menu **

-DRIVE-

Operation

** Main Menu **

-QUICK-

Quick Setting

** Main Menu **

-ADV-

Programming

** Main Menu **

-VERIFY-

Modified Consts

** Main Menu **

-A.TUNE-

Auto-Tuning

MENU

Initialization

-ADV-

A1

-00=1

Select Language

MENU

MENU

MENU

MENU

ESC

DATA

ENTER

Select Language

-ADV-

A1-

00

=0

English

ESC

-ADV-

Select Language

English

*1*

ESC

DATA

ENTER

RESET

Monitor Display

Setting Display

Mode Selection Display

PID Control

-ADV-

b5

-01=0

PID Mode

ESC

ESC

DATA

ENTER

RESET

Control Method

-ADV-

A1-

02

=2

Open Loop Vector

PID Mode

-ADV-

b5-

01

=0

Disabled

Control Method

-ADV-

A1- 02=

2

Open Loop Vector

ESC

DATA

ENTER

*2*

*1*

*2*

1

2

1

2

PID Mode

-ADV-

b5-01=

0

Disabled

*0*

*0*

Fb los Det Time

-ADV-

b5-

14

= 1.0Sec

Fb los Det Time

-ADV-

b5-14=

0

1.0Sec

ESC

DATA

ENTER

3

4

3

4

Torque Limit

-ADV-

L7

-01=200%

Fwd Torque Limit

ESC

ESC

DATA

ENTER

RESET

ESC

DATA

ENTER

5

6

5

6

Fwd Torque Limit

-ADV-

L7-

01

= 200%

Fwd Torque Limit

-ADV-

L7-01=

2

00%

Torq Lmt Rev Rgn

-ADV-

L7-04=

2

00%

Fwd Torque Limit

-ADV-

L7-

04

= 200%

A

B

A

B

Initialization

-ADV-

A1

- 02

=2

Control Method

ESC

RESET

PID Control

-ADV-

b5

- 14= 1.0Sec

Fb los Det Time

ESC

RESET

Fwd Torque Limit

-ADV-

L7-

04

= 200%

Torque Limit

ESC

RESET

Advertising