Setting example – Yaskawa G7 Drive User Manual

Page 235

Advertising
background image

6

-18

Fig 6.19 Acceleration/Deceleration Time Gain Using an Analog Input

„

Entering S-curve Characteristics in the Acceleration and Deceleration Time

By performing acceleration and deceleration using an S-curve pattern, you can reduce shock when starting and
stopping the machine.

Using the Drive, you can set an S-curve characteristic time for each of the following: Acceleration start time,
deceleration start time, acceleration end time, and deceleration end time.

Setting Example

The S-curve characteristic when switching operation (forward/reverse) is shown in the following diagram.

Fig 6.20 S-curve Characteristic during Operation Switching

INFO

Set the S-curve characteristic time to lengthen acceleration/deceleration time as follows:

Acceleration time = Selected acceleration time + (Acceleration start time S-curve characteristic time +

Acceleration end time S-curve characteristic time) / 2

Deceleration time = Selected deceleration time + (Deceleration start time S-curve characteristic time +

Deceleration end time S-curve characteristic time) / 2

Acceleration/deceleration time gain (set value: 5)

(Acceleration/deceleration gain from 1 to
10 V) = 10 V/Input voltage (V) x 10 (%)

C2-02

C2-01

C2-03

C2-04

C2-02

C2-01

C2-03

C2-04

Forward

Reverse

Output frequency

Advertising