Limiting motor rotation direction, Related parameters, Limiting motor rotation direction -56 – Yaskawa G7 Drive User Manual

Page 273

Advertising
background image

6

-56

Fig 6.41 Mutual Connections During Motor Overheating Protection

‹

Limiting Motor Rotation Direction

If you set motor reverse rotation prohibited, a reverse run command will not be accepted even if it is input.
Use this setting for applications in which reverse motor rotation can cause problems (e.g., fans, pumps, etc.)

„

Related Parameters

Parameter

Number

Name

Description

Setting
Range

Factory

Setting

Change

during

Operation

Control Methods

Display

V/f

V/f

with

PG

Open

Loop

Vector

1

Flux

Vector

Open

Loop

Vector

2

b1-04

Reverse
Operation
Selection

Determines the forward rotation
of the motor, and if reverse
operation is disabled.
0: Reverse enabled.
1: Reverse disabled.

0 to 1

0

No

A

A

A

A

A

Reverse Oper

Drive

Multi-function

contact input

Branch resistance

18 k

Ω

PTC thermistor

Multi-function

contact output

Multi-function

PHC output

Fault contact

output

P3

C3

C4

P4

Advertising