Field control: d6 – Yaskawa G7 Drive User Manual

Page 144

Advertising
background image

User Parameter Tables

5-

33

„

Field Control: d6

User parameters for the field weakening command are shown in the following table.

Parameter

Number

Name

Description

Setting

Range

Factory

Setting

Change

during

Operation

Control Methods

MODBUS

Register

Display

V/f

V/f

with

PG

Open

Loop

Vector

1

Flux

Vector

Open

Loop

Vector

2

d6-01

Magnetic
Field
Weakening
Level

Sets the Drive output voltage
when the multi-function input
"field weakening command"
is input (H1-xx = 63). Sets as
a percentage taking the
voltage set in the V/f pattern
as 100%.

0

to

100

80%

No

A

A

No

No

No

2A0H

Field-Weak
Lvl

d6-02

Magnetic
Field
Frequency

Sets the lower limit (in Hz) of
the frequency range where
field weakening control is
valid. The field weakening
command is valid only at
frequencies above this setting
and only when output
frequency is in agreement
with the current output
frequency (speed agree).

0.0

to

400.0

0.0HzH

z

No

A

A

No

No

No

2A1H

Field-Weak
Freq

d6-03

Magnetic
Field Forcing
Function
Selection

Set the magnetic field forcing
function.

0: Disabled
1: Enabled

0 or 1

0

No

No

No

A

A

A

2A2H

Field Force
Sel

d6-05

A

φR Time

Constant

Sets the A-phase-R time
constant in relation to the
motor secondary circuit time
constant by the amount of
increase.

Note: A-phase-R Time

Constant = (Secondary
Circuit Time Constant)
x (d6-05).

When d6-05 = 0, then
A-phase-R is inactive.

When d6-05 = 0, it
becomes the lower limit
for 200ms internal to the
drive.

0.00

to

10.00

1.00

No

No

No

No

No

A

2A4H

A PHI R
Filter

d6-06

Magnetic
Field Forcing
Limit

Sets the upper limit of the
excitation current command
during magnetic field forcing.
A setting of 100% is equal to
motor no-load current, E2-03.

100

to

400

400%

No

No

No

A

A

A

2A5H

Field Force
Limit