Related parameters – Yaskawa G7 Drive User Manual

Page 285

Advertising
background image

6

-68

‹

Reducing Drive Overheating Pre-Alarm Warning Levels

The Drive detects the temperature of the cooling fins using the thermistor, and protects the Drive from over-
heating. You can receive Drive overheating pre-alarms in units of 10

°

C.

The following overheating pre-alarm warnings are available: Stopping the Drive as error protection, and con-
tinuing operation, with the alarm OH (Radiation fins overheating) on the Digital Operator flashing.

„

Related Parameters

* Factory settings will vary based on drive capacity.

Parameter

Number

Name

Description

Setting
Range

Factory

Setting

Change

during

Operation

Control Methods

Display

V/f

V/f

with

PG

Open

Loop

Vector

1

Flux

Vector

Open

Loop

Vector

2

L8-02

Overheat Alarm
Level

When the cooling fin temperature
exceeds the value set in this
parameter, an Overheat Alarm
(OH) will occur.

50

to

130

95

°C*

No

A

A

A

A

A

OH Pre-Alarm
Lvl

L8-03

Overheat
Pre-Alarm
Operation
Selection

Selects the Drive operation upon
an OH pre-alarm detection.
0: Ramp to Stop
1: Coast to Stop
2: Fast-Stop
3: Alarm Only

0 to 3

3

No

A

A

A

A

A

OH Pre-Alarm
Sel

Advertising