Related parameters – Yaskawa G7 Drive User Manual

Page 353

Advertising
background image

6

-136

„

Related Parameters

Parameter

Number

Name

Description

Setting
Range

Factory

Setting

Change

during

Operation

Control Methods

Display

V/f

V/f

with

PG

Open

Loop

Vector

1

Flux

Vector

Open

Loop

Vector

2

b2-01

DC Injection
Braking Start
Frequency

Sets the frequency at which DC
injection braking starts when
ramp to stop (b1-03 = 0) is
selected. If b2-01< E1-09, DC
Injection braking starts at E1-09.
Note: Zero Speed restrictions are
active in Flux Vector Mode.

0.0

to

10.0

0.5Hz

No

A

A

A

A

A

DCInj Start
Freq

b9-01

Zero Servo
Gain

Sets the position loop gain for
Zero Servo command. This
function is effective when
multi-function input "zero servo
command" is set.

0 to 100

5

No

No

No

No

A

No

Zero Servo
Gain

b9-02

Zero Servo
Completion
Width

Sets number of pulses used for the
multi-function output of "zero
servo completion".

0

to

16383

10

No

No

No

No

A

No

Zero Servo
Count