Yaskawa G7 Drive User Manual

Page 210

Advertising
background image

User Parameter Tables

5-

99

208-240Vac and 380-480Vac Drives of 2.2 to 45 kW

Table 5.4 V/F Pattern for Drive Capacity G7U22P2 - 2045 for 208-240V Class

Parameter

No.

Name

Unit

Factory Setting

E1-03

V/F Pattern Selection

0

1

2

3

4

5

6

7

E1-04

Max. Output Frequency

Hz

50.0

60.0

60.0

72.0

50.0

50.0

60.0

60.0

E1-05

Max. Output Voltage

V

230.0

230.0

230.0

230.0

230.0

230.0

230.0

230.0

E1-06

Base Frequency

Hz

50.0

60.0

50.0

60.0

50.0

50.0

60.0

60.0

E1-07

Mid. Output Frequency

V

2.5

3.0

3.0

3.0

25.0

25.0

30.0

30.0

E1-08

Mid. Output Voltage

V

16.1

16.1

16.1

16.1

40.2

57.5

40.2

57.5

E1-09

Min. Output Frequency

Hz

1.3

1.5

1.5

1.5

1.3

1.3

1.5

1.5

E1-10

Min. Output Voltage

V

8.0

8.0

8.0

8.0

6.9

8.0

6.9

8.0

1.

The setting shown are for 208-240Vac Drives. The values will double for 380-480Vac Drives.

2. These default values are for V/F or V/F with PG control methods (A1-02 = 0 or 1)

Table 5.4 V/F Pattern for Drive Capacity G7U22P2 - 2045 for 208-240V Class (continued)

Parameter

No.

Name

Unit

Factory Setting

E1-03

V/F Pattern Selection

8

9

A

B

C

D

E

F &

FF

E1-04

Max. Output Frequency

Hz

50.0

50.0

60.0

60.0

90.0

120.0

180.0

60.0

E1-05

Max. Output Voltage

V

230.0

230.0

230.0

230.0

230.0

230.0

230.0

230.0

E1-06

Base Frequency

Hz

50.0

50.0

60.0

60.0

60.0

60.0

60.0

60.0

E1-07

Mid. Output Frequency

V

2.5

2.5

3.0

3.0

3.0

3.0

3.0

3.0

E1-08

Mid. Output Voltage

V

20.7

26.4

20.7

26.4

16.1

16.1

16.1

16.1

E1-09

Min. Output Frequency

Hz

1.3

1.3

1.5

1.5

1.5

1.5

1.5

1.5

E1-10

Min. Output Voltage

V

10.3

12.6

10.3

14.9

8.0

8.0

8.0

8.0

1. For 400V class units, the voltage values are twice that of 200V class units.
2. These default values are for V/F or V/F with PG control methods (A1-02 = 0 or 1)

Advertising