Operation during motor overheating, Error codes if the motor overheats – Yaskawa G7 Drive User Manual

Page 272

Advertising
background image

Machine Protection

6-

55

„

PTC Thermistor Characteristics

The following diagram shows the characteristics of the PTC thermistor temperature to the resistance value.

Fig 6.40 PTC Thermistor Temperature-Resistance Value Characteristics

„

Operation during Motor Overheating

Set the operation if the motor overheats in parameters L1-03 and L1-04. Set the motor temperature input filter
time parameter in L1-05. If the motor overheats, the OH3 and OH4 error codes will be displayed on the Digi-
tal Operator.

Error Codes If the Motor Overheats

By setting H3-09 (Multi-function Analog Input Terminal A2 Function Selection) or H3-05 (Multi-function
Analog Input Terminal A3 Function Selection) to E (Motor temperature input), you can detect alarm OH3 or
OH4 using the PTC temperature-resistance characteristics, and protect the motor. The terminal connections
are shown in the following diagram.

Error Code

Details

OH3

Drive stops or continues to operate, according to the setting in L1-03.

OH4

Drive stops according to the setting in L1-04.

Tr: Temperature threshold value

Tr+5

Tr

550

1330

Resistance (ohms)

Class F

150

°C

Class H

180

°C

Temperature