Torque limits: l7 – Yaskawa G7 Drive User Manual

Page 182

Advertising
background image

User Parameter Tables

5-

71

„

Torque Limits: L7

User parameters for torque limits are shown in the following table.

Parameter

Number

Name

Description

Setting

Range

Factory

Setting

Change

during

Operation

Control Methods

MODBUS

Register

V/f

V/f

with

PG

Open

Loop

Vector

1

Flux

Vector

Open

Loop

Vector

2

L7-01

Forward
Torque
Limit

Sets the torque limit value as a
percentage of the motor rated torque.
Four individual quadrants can be set.

0

to

300

200%

No

No No

A

A

A

4A7H

Torq Limit
Fwd

L7-02

Reverse
Torque
Limit

0

to

300

200%

No

No No

A

A

A

4A8H

Torq Limit
Rev

L7-03

Forward
Regenerative
Torque
Limit

0

to

300

200%

No

No No

A

A

A

4A9H

Torq Lmt
Fwd Rgn

L7-04

Reverse
Regenerative
Torque
Limit

0

to

300

200%

No

No No

A

A

A

4AAH

Torq Lmt
Rev Rgn

L7-06

Torque
Limit
Integral
Time
Constant

Sets the torque limit value as a per-
centage of the motor rated torque. Four
individual quadrants can be set.

5

to

10000

200ms

No

No No

A

No

No

4ACH

Torq Det 2
Time

L7-07

Torque
Limit
Control
Method
Selection
During
Accel/
Decel

Selects the method of torque limit
controls during accel/decel
0: Proportional Controls (uses integral

controls at fixed speeds).

1: Integral Controls

Adjustment is not normally
required. With applications that
require torque limits during
accel/decel, integral controls (setting
value = 1) are used when torque
controls take precedence. When
torque limit is applied to the motor,
accel/decel time may increase and
motor speed may not run at the
indicated speed reference.

0 to 1

0

No

No No

A

No

No

4C9H

Torq Lmt
Sel

Output torque

Positive torque

Reverse

Negative torque

No. of

motor

rotations

Regenerative

state

Regenerative

state

Forward