6-

119

Fig 6.63 User-Set V/f Pattern

If one of the custom V/f patterns is selected, then parameters E1-04 through E1-13 will determine the V/f pattern.

„

Setting Precautions

When the setting is to user-defined V/f pattern, beware of the following points.

When changing control method, parameters E1-07 to E1-10 will change to the factory settings for that
control method.

Be sure to set the four frequencies as follows:
E1-04 (FMAX)

≥ E1-06 (FA) > E1-07 (FB) ≥ E1-09 (FMIN)

Table 8 Preset V/f Patterns

Specifications

E1-03

V/f Pattern *1

Specifications

E1-03

V/f Pattern *1

General-purpose

50Hz

0

High Starting Torqu

e *2

50Hz

High

Starting

Torque 1

8

High

Starting

Torque 2

9

60Hz Saturation

1
F

60Hz

High

Starting

Torque 1

A

50Hz Saturation

2

High

Starting

Torque 2

B

72Hz

3

High

Speed

Op

eration

90Hz

C

Variable Torque

50Hz

Variable

Torque 1

4

120Hz

D

Variable

Torque 2

5

60Hz

Variable

Torque 1

6

180Hz

E

Variable

Torque 2

7

IMPORTANT

When a factory Initialization is performed, the setting of E1-03 is unaffected but the settings of E1-04
through E1-13 are returned to their factory default settings.

(Hz)

(V)

230

17
10

0 1.3 2.5

50

0

230

(V)

28

22

15

13

(Hz)

0 1.3 2.5

50

9

8

(Hz)

0 1.5 3.0

50 60

17
10

2

1
F

(V)

230

230

(V)

28

22

17

13

(Hz)

0 1.5 3.0

B

A

60

(Hz)

0 1.5 3.0

60 72

17
10

3

(V)

230

(Hz)

0 1.5 3.0

60 90

17
10

C

(V)

230

230

(V)

57
40

10

9

(Hz)

0 1.3

25

50

5

4

(Hz)

0 1.5 3.0

60 120

17
10

D

(V)

230

230

(V)

57
40

10

9

(Hz)

0 1.5

30

60

7

6

(Hz)

0 1.5 3.0

60 180

17
10

E

(V)

230