Multi-function analog input (h3-05, h3-09) – Yaskawa G7 Drive User Manual

Page 267

Advertising
background image

6

-50

‹

Changing Overtorque and Undertorque Detection Levels Using an Ana-
log Input

If you set parameter H3-09 (Multi-function Analog Input Terminal A2 Function Selection) or H3-05 (Multi-
function Analog Input Terminal A3 Function Selection) to 7 (overtorque/undertorque detection level), you can
change the overtorque/undertorque detection level.

If you change the overtorque/undertorque detection level using the multi-function analog input, only over-
torque/undertorque detection level 1 will be enabled.

The following diagram shows the overtorque/undertorque detection level using an analog input.

Fig 6.38 Overtorque/Undertorque Detection Level Using an Analog Input

Multi-Function Analog Input (H3-05, H3-09)

Setting

Value

Function

Contents (100%)

Control Methods

V/f

V/f

with

PG

Open

Loop

Vector

1

Flux

Vector

Open

Loop

Vector

2

7

Overtorque/undertorque detection
level

Motor rated torque for vector control
Drive rated output current for V/f control

Yes

Yes

Yes

Yes

Yes

Detection level

Multi-function analog input
terminal A2, A3 input level

(4 mA)

(20 mA)

Advertising