Related parameters – Yaskawa G7 Drive User Manual

Page 236

Advertising
background image

Acceleration and Deceleration Characteristics

6-

19

‹

Accelerating and Decelerating Heavy Loads (Dwell Function)

The dwell function stores the output frequency when starting or stopping heavy loads. By temporarily storing
the output frequency, you can prevent the motor from stalling. When using the dwell function, you must select
a deceleration stop. Set b1-03 (Stopping Method Selection) to 0.

„

Related Parameters

Parameter

Number

Name

Description

Setting

Range

Factory

Setting

Change

during

Operation

Control Methods

Display

V/f

V/f

with

PG

Open

Loop

Vector

1

Flux

Vector

Open

Loop

Vector

2

b6-01

Dwell
Reference at
Start

The dwell function is used to temporarily
hold the frequency when driving a motor
with heavy load.

0.0

to

400.0

0.0Hz

No

A

A

A

A

A

Dwell Ref
@Start

b6-02

Dwell Time
at Start

0.0

to

10.0

0.0sec

No

A

A

A

A

A

Dwell
Time@Start

b6-03

Dwell
Frequency at
Stop

0.0

to

400.0

0.0Hz

No

A

A

A

A

A

Dwell Ref
@Stop

b6-04

Dwell Time
at Stop

0.0

to

10.0

0.0sec

No

A

A

A

A

A

Dwell Time
@Stop

Run command

Output frequency

Time

ON

b6-03

OFF

b6-01

b6-04

b6-02