Setting the Torque Limit in Parameters

Using L7-01 to L7-04, you can set individually four torque limits in the following directions: Forward drive,
reverse drive, forward regeneration, and reverse regeneration.

„

Set the Torque Limit Value Using an Analog Input

You can change the analog input level torque limit value by setting the torque limit in multi-function analog
input terminals A2 and A3.

The analog input terminal signal level is factory-set as follows:

Multi-function analog input terminal A2: 4 to 20mA
Multi-function analog input terminal A3: 0 to 10

The following diagram shows the relationship between the torque limits.

Fig 6.35 Torque Limit by Analog Input

„

Setting Torque Limits Using Parameters and an Analog Input

The following block diagram shows the relationship between torque limit using parameters and torque limit
using an analog input.

Fig 6.36 Torque Limit Using Parameters and an Analog Input

Negative

Reverse operation

Regenerative torque limit

Regenerative torque limit

Forward torque limit

Positive/negative torque limits

Positive/negative torque limits

No. of motor rotations
Forward operation

Negative torque limit

Positive

Output torque

Multi-function analog input

Terminal

A2 or A3

Forward torque limit

(set value = 10)
Negative torque limit

(set value = 11)
Regenerative torque limit

(set value = 12)

Positive/negative torque limit

(set value = 15)

Positive forward drive
torque

Reverse positive regenerative torque

Forward negative regenerative torque

Reverse

drive

reverse

torque

Min: Minimum value priority circuit

Parame-

Forward torque limit

(L7-01)

Reverse torque limit

(L7-02)
Forward regenerative torque

limit (L7-03)

Reverse regenerative torque

limit (L7-04)

175% of Drive rated current

Forward torque limit

Reverse torque limit

Forward regenerative

torque limit
Reverse regenerative

torque limit