User Parameter Tables

5-

105

Parameter

Number

Name

Unit

Factory Setting

-

Drive Capacity

kW

18.5

22

30

37

45

o2-04

kVA selection

-

2A

2B

2C

2D

2E

b8-03

Energy Saving Control
Filter Time Constant

s

0.50 (Open-loop vector control)

b8-04

Energy Saving Coefficient
Value

-

115.74

103.58

92.54

76.32

71.56

C6-02

Carrier Frequency Selection

*1

-

3

3

3

3

3

C6-11

Carrier Frequency Selection
for Open Loop Vector 2

*2

-

3

3

3

3

3

-

Carrier frequency selection
upper limit

-

3

3

3

3

3

E2-01

(E4-01)

Motor Rated Current

A

32.9

38.6

52.3

65.6

79.7

E2-02

(E4-02)

Motor Rated Slip

Hz

1.67

1.70

1.80

1.33

1.60

E2-03

(E4-03)

Motor No-Load Current

A

7.8

9.2

10.9

19.1

22.0

E2-05

(E4-05)

Motor Line-to-Line
Resistance

Ω

0.403

0.316

0.269

0.155

0.122

E2-06

(E4-06)

Motor Leakage Inductance

%

20.1

23.5

20.7

18.8

19.9

E2-10

Motor Iron Loss for Torque
Compensation

W

508

586

750

925

1125

L2-02

Momentary Power Loss
Ride-thru Time

s

2.0

2.0

2.0

2.0

2.0

L2-03

Momentary Power Loss
Minimum Base Block Time

s

1.0

1.1

1.1

1.2

1.2

L2-04

Momentary Power Loss
Voltage Recovery Ramp
Time

s

0.6

0.6

0.6

0.6

1.0

L8-02

Overheat Alarm Level

°C

95

95

95

95

95

n5-02

Motor Acceleration Time

s

0.317

0.355

0.323

0.320

0.387