Yaskawa G7 Drive User Manual

Page 304

Advertising
background image

Individual Functions

6-

87

* If H5-01 is set to zero, then the drive will be unable to respond to Modbus communication.

H5-05

Communicati
on Fault
Detection
Selection

Enables or disables the

communications timeout fault
(CE).

0: Disabled - A communication

loss will not cause a
communication fault.

1: Enabled - If communication is

lost for more than 2 seconds, a
CE fault will occur.

0 or 1

1

No

A

A

A

A

A

Serial Flt Dtct

H5-06

Drive
Transmit Wait
Time

Set the delay time from when the
Drive receives data to when the
Drive sends data.

5 to 65

5ms

No

A

A

A

A

A

Transmit
WaitTIM

H5-07

RTS Control
Selection

Enables or disables "request to
send" (RTS) control:
0: Disabled - RTS is always on
1: Enabled - RTS turns on only

when sending

0 or 1

1

No

A

A

A

A

A

RTS Control
Sel

Parameter

Number

Name

Description

Setting
Range

Factory

Setting

Change

during

Operation

Control Methods

Display

V/f

V/f

with

PG

Open

Loop

Vector

1

Flux

Vector

Open

Loop

Vector

2