Torque compensation: c4 – Yaskawa G7 Drive User Manual

Page 136

Advertising
background image

User Parameter Tables

5-

25

„

Torque Compensation: C4

User parameters for are torque compensation shown in the following table.

* The display shows the factory settings for Open loop vector 1 (OLV1). Default settings will change in accordance with the control mode.

Parameter

Number

Name

Description

Setting

Range

Factory

Setting

Change

during

Operation

Control Methods

MODBUS

Register

Display

V/f

V/f

with

PG

Open

Loop

Vector

1

Flux

Vector

Open

Loop

Vector

2

C4-01

Torque
Compensation
Gain

This parameter sets the gain
for the Drive's automatic
torque boost function to
match the Drive's output
voltage to the motor load.
This parameter helps to
produce better starting torque.
It determines the amount of
torque or voltage boost based
upon motor current, motor
resistance, and output
frequency.
Note: Adjustment is not

normally required.

0.00

to

2.50

1.00

Yes

A

A

A

No

No

215H

Torq Comp
Gain

C4-02

Torque
Compensation
Primary
Delay Time

This parameter adjusts the
filter on the output of the
torque compensation
function. Increase to add
stability, decrease to improve
response.
Note: Adjustment is not

normally required.

0

to

10000

20ms*

No

A

A

A

No

No

216H

Torq Comp
Time

C4-03

Torque
Compensation
at Forward
Start

Sets torque compensation at
forward start as a percentage
of motor torque.

0.0

to

200.0

0.0%

No

No

No

A

No

No

217H

F TorqCmp@
start

C4-04

Torque
Compensation
at Reverse
Start

Sets torque compensation at
reverse start as a percentage
of motor torque.

-200.0

to

0.0

0.0%

No

No

No

A

No

No

218H

R TorqCmp@
start

C4-05

Torque
Compensation
Time
Constant

Sets the time constant for
torque compensation at
forward start and reverse start
(C4-03 and C4-04). The filter
is disabled if the time is set to
4ms or less.

0

to

200

10ms

No

No

No

A

No

No

219H

TorqCmp
Delay T