Drive protection, Related parameters, Multi-function contact outputs (h2-01 to h2-05) – Yaskawa G7 Drive User Manual

Page 284: Drive protection -67

Advertising
background image

Drive Protection

6-

67

Drive Protection

This section explains the functions for protecting the Drive and the braking resistor.

‹

Performing Overheating Protection on Mounted Braking Resistors

Perform overheating protection on Drive-mounted braking resistors (Model: ERF-150WJ ††).

When overheating in a mounted braking resistor is detected, an alarm RH (Mounted braking resistor overheat-
ing) is displayed on the Digital Operator, and the motor coasts to a stop.

„

Related Parameters

Multi-function Contact Outputs (H2-01 to H2-05)

Parameter

Number

Name

Description

Setting
Range

Factory

Setting

Change

during

Operation

Control Methods

Display

V/f

V/f

with

PG

Open

Loop

Vector

1

Flux

Vector

Open

Loop

Vector

2

L8-01

Internal
Dynamic
Braking
Resistor
Protection
Selection

Selects the DB protection only

when using 3% duty cycle
heatsink mount Yaskawa braking
resistor. This parameter does not
enable or disable the DB
function of the Drive.

0: Not Provided
1: Provided

0 to 1

0

No

A

A

A

A

A

DB Resistor
Prot

Setting

Value

Function

Control Methods

V/f

V/f

with

PG

Open

Loop

Vector

1

Flux

Vector

Open

Loop

Vector

2

D

Braking resistor fault (ON: Resistor overheat or braking transistor fault)

Yes

Yes

Yes

Yes

Yes

INFO

The most likely causes of RH (Mounted braking resistor overheating) being detected are that the deceleration
time is too short or that the motor regeneration energy is too large. In these cases, lengthen the deceleration
time or replace the Braking Resistor Unit with one with a higher breaking capacity.