Wiring the pg-b2 – Yaskawa G7 Drive User Manual

Page 69

Advertising
background image

2

-38

„

Wiring the PG-B2

Wiring examples are provided in the following illustrations for the PG-B2.

Shielded twisted-pair wires must be used for signal lines.

Do not use the pulse generator's power supply for anything other than the pulse generator (encoder).
Using it for another purpose can cause malfunctions due to noise.

The length of the pulse generator's wiring must not be more than 100 meters (328 ft).

The direction of rotation of the PG can be set in user parameter F1-05. The factory preset if for forward
rotation, A-phase advancement.

Fig 2.22 PG-B2 Wiring

When connecting to a voltage-output-type PG (encoder), select a PG that has an output impedance with
a current of at least 12 mA to the input circuit photocoupler (diode).

The pulse monitor dividing ratio can be changed using parameter F1-06.

Fig 2.23 I/O Circuit Configuration of the PG-B2

Three-phase
200-240 Vac
(380-480 Vac)

Drive

Power supply +12 Vdc

Power supply 0 Vdc

A-phase pulse output (+)

A-phase pulse output (-)

B-phase pulse output (+)

B-phase pulse output (-)

A-phase pulse monitor output

B-phase pulse monitor output

PG power

supply +12

Vdc

A-phase pulse

input

B-phase pulse

input

A-phase

pulses

B-phase

pulses

Divisi

on

rate

c

ircu

it

B-phase pulse

monitor output

A-phase pulse

monitor output

A-phase pulses

B-phase pulses

Advertising