Wiring the PG-B2

Wiring examples are provided in the following illustrations for the PG-B2.

•

Shielded twisted-pair wires must be used for signal lines.

•

Do not use the pulse generator's power supply for anything other than the pulse generator (encoder).
Using it for another purpose can cause malfunctions due to noise.

•

The length of the pulse generator's wiring must not be more than 100 meters (328 ft).

•

The direction of rotation of the PG can be set in user parameter F1-05. The factory preset if for forward
rotation, A-phase advancement.

Fig 2.22 PG-B2 Wiring

•

When connecting to a voltage-output-type PG (encoder), select a PG that has an output impedance with
a current of at least 12 mA to the input circuit photocoupler (diode).

•

The pulse monitor dividing ratio can be changed using parameter F1-06.

Fig 2.23 I/O Circuit Configuration of the PG-B2