background image

Input Terminal Functions

6-

77

„

Setting Precautions

To switch command inputs between the Communications Option Card and the control circuit terminals, set the
following parameters.

Set b1-01 (Reference Selection) to 1 (Control circuit terminal [analog input])

Set b1-02 (Operation Method Selection to 1 (Control circuit terminal (sequence inputs])

Set one of the parameters H1-01 to H1-10 (multi-function contact input terminal S3 to S12 function selec-
tion) to 2 (Option/Drive selection).

‹

Jog Frequency Operation without Forward and Reverse Commands
(FJOG/RJOG)

The FJOG/RJOG command functions operate the Drive using jog frequencies by using the terminal ON/OFF
operation. When using the FJOG/RJOG commands, there is no need to input the run command.
To use this function, set one of the parameters H1-01 to H1-10 (multi-function contact input terminal S3 to
S12 function selection) to 12 (FJOG command) or 13 (RJOG command).

„

Related Parameters

*1 Setting range changes to 0 thru 66.0 when operating in Vector 2 wo/PG.. The upper limit for the setting range also depends on the upper limit in E1-

04. The max setting is 400.00.

Multi-Function Contact Inputs (H1-01 to H1-10)

„

Application Precautions

Jog frequencies using FJOG and RJOG commands are given priority over other frequency references.

When both FJOG command and RJOG commands are ON for 500ms or longer at the same time, the Drive
stops according to the setting in b1-03 (stopping method selection).

Terminal Status

Frequency Reference and Run Command Selection

OFF

Drive
(Can be operated from frequency reference or control circuit terminal from analog input termi-
nal.)

ON

Communications Option Card
(Frequency reference and run command are enabled from communications Option Card.)

Parameter

Number

Name

Description

Setting
Range

Factory

Setting

Change

during

Operation

Control Methods

Display

V/f

V/f

with

PG

Open

Loop

Vector

1

Flux

Vector

Open

Loop

Vector

2

d1-17

Jog Frequency
Reference

Frequency reference when: "Jog
frequency reference" is selected
via multi-function input
terminals. "Jog frequency
reference" has priority over
"multi-step speed reference 1 to
4". Parameter d1-17 is also the
reference for the JOG key on the
Digital Operator, and the multi-
function inputs "forward jog" and
"reverse jog". Setting units are
affected by o1-03.

0.00

to

400.00

*1

6.00Hz

Yes

Q

Q

Q

Q

Q

Jog Reference

Setting

Value

Function

Control Methods

V/f

V/f

with

PG

Open

Loop

Vector

1

Flux

Vector

Open

Loop

Vector

2

12

FJOG command (ON: Forward run at jog frequency d1-17)

Yes

Yes

Yes

Yes

Yes

13

RJOG command (ON: Reverse run at jog frequency d1-17)

Yes

Yes

Yes

Yes

Yes