3 torque control, Torque control function settings: d5-01 – Yaskawa G5HHP Drive User Manual

Page 183

Advertising
background image

7.3 Flux Vector Control

7 - 19

D

To output the zero-servo status externally, assign the Zero Servo End signal (setting 33) to one of the

multi-function outputs (H2-01 to H2-03). The setting in b9-02 (Zero-servo Completion Width) is en-

abled when one of the multi-function outputs has been set to 33.

D

The Zero Servo End signal remains ON as long as the position is within this range (starting position ±

Zero-servo Completion Width).

D

Set the Zero-servo Completion Width to four times the number of pulses from the PG (pulse generator

or encoder), as shown in Figure 7.8.

For example, when a 600 p/r encoder is being used, the number of pulses would be 2,400 p/r after multi-

plying by four.

D

The Zero Servo End signal will go OFF when the zero servo command is turned OFF.

D

Do not lock the servo for extended periods of time at 100% when using the zero servo function. Extended

periods of servo lock can be achieved by ensuring that the current during the servolock is 50% or less

or by increasing the Inverter capacity.

Phase A

Phase B

1 pulse

Count

1

2

3

4

5 6

7

8

9 10 11 12

Factor of 4: By counting the rising and

falling edges of phase A

this method has four times

the resolution of the PG.

Fig 7.8

Pulse Count Factored by 4

7.3.3 Torque Control

J

Torque Control Function Settings: d5-01

With flux vector control, the motor’s output torque can be controlled by a torque reference from an analog

input.

User

Change

during

Setting

Factory

Valid Access Levels

User

Constant

Number

Name

g

during

Opera-

tion

Setting

Range

Unit Factory

Setting

V/f

Control

V/f with

PG

Open

Loop

Vector

Flux

Vector

d5-01

Torque control selec-

tion

x

0, 1

--

0

x

x

x

A

D

Settings

Setting

Function

0

Speed control (controlled by C5-01 to C5-07)

1

Torque control

D

Set constant d5-01 to “1” to select torque control.

D

Figure 7.9 shows the operation of torque control.