Yaskawa G5HHP Drive User Manual

Page 253

Advertising
background image

7.5 Common Functions

7 - 89

Output current

Time

L3-02 (Acceleration stall prevention level)

Output frequency

Time

The output frequency is controlled to prevent stalling.

Fig 7.43

Acceleration Stall Prevention Function: L3-01 = 1

Stall Prevention Limit During Acceleration: L3-03

User

Change

during

Setting

Factory

Valid Access Levels

User

Constant

Number

Name

g

during

Opera-

tion

Setting

Range

Unit Factory

Setting

V/f

Control

V/f with

PG

Open

Loop

Vector

Flux

Vector

L3-03

Stall prevention limit

during accel

x

0 to 100

%

50

A

A

A

x

D

Normally it isn’t necessary to change this setting.

D

Set this constant when a high-speed motor is being used in the high-speed range (the high frequency

range above the base frequency).

D

The standard target setting is the motor’s rated current. Set this current value as a percentage of the In-

verter’s rated current, i.e., 100% corresponds to the Inverter’s rated current.

E1-06

Base frequency (F

A

)

Acceleration stall

prevention level

L3-02

(Acceleration stall preven-

tion level)

L3-03

(Acceleration stall prevention

limit)

Output frequency

Note When the motor is used in the high-speed range, the acceleration stall prevention level

is automatically lowered to provide smoother acceleration.

The acceleration stall prevention limit (L3-03) limits how much the acceleration stall

prevention level is lowered so that it isn’t lowered any more than necessary.

Fig 7.44

Stall Prevention Limit During Acceleration

7