Torque compensation: c4 – Yaskawa G5HHP Drive User Manual

Page 278

Advertising
background image

User Constants

8.2.2 Autotuning Constants: C

8 - 12

Constant

Number

Page

Control Methods

Change

during

Opera-

tion

Factory

Setting

Setting

Range

Description

Name

Constant

Number

Page

Flux

Vector

Open

Loop

Vector

V/f

with

PG

V/f

Change

during

Opera-

tion

Factory

Setting

Setting

Range

Description

Display

C3-05

Flux calculation meth-

od

Used to set the flux calculation

method.
0: Flux is calculated based on the

output frequency after com-

pensation

0, 1

0

x

x

x

A

x

----

C3 05

Flux Select

pensation.

1: Flux is calculated based on the

output frequency before com-

pensation.

0, 1

0

x

x

x

A

x

----

* When the control method is changed, the Inverter reverts to factory settings. (The open loop vector control factory settings will

be displayed.)

J

Torque Compensation: C4

C

t t

Name

S tti

F t

Change

Control Methods

Constant

Number

Display

Description

Setting

Range

Factory

Setting

Change

during

Opera-

tion

V/f

V/f

with

PG

Open

Loop

Vector

Flux

Vector

Page

C4-01

Torque compensation

gain

Sets torque compensation gain as a

ratio.
;

Usually setting is not necessary.

Adjust in the following circum-

stances:

S

When the cable is long; increase

the set value.

S

When the motorcapacity is small-

er than the Inverter capacity

0.00 to

2 50

1.00

f

B

B

B

x

7 - 52

C4 01

Torq Comp Gain

er than the Inverter capacity

(Max. applicable motor capac-

ity), increase the set values.

S

When the motor is oscillating, de-

crease the set values.

Adjust the output current range at

minimum speed rotation so that it

does not exceed the Inverter rated

output current.

2.50

1.00

f

B

B

B

x

7 - 52

C4-02

Torque compensation

time constant

The torque compensation delay

time is set in ms units.
;

Usually setting is not necessary.

Adjust in the following circum-

stances:

S

Wh th

t i

ill ti

i

0 to

10000

20 *

x

A

A

A

x

7 - 52

C4 02

Torq Comp Time

S

When the motor is oscillating, in-

crease the set values.

S

When the responsiveness of the

motor is low, decrease the set val-

ues.

10000

20

x

A

A

A

x

7 - 52

* When the control method is changed, the Inverter reverts to factory settings. (The open loop vector control factory settings will

be displayed.)

8