User Constants

8.2.3 Reference Constants: d

8 - 18

Constant

Number

Page

Control Methods

Change

during

Opera-

tion

Factory

Setting

Setting

Range

Description

Name

Constant

Number

Page

Flux

Vector

Open

Loop

Vector

V/f

with

PG

V/f

Change

during

Opera-

tion

Factory

Setting

Setting

Range

Description

Display

d5-02

Torque reference

delay time

Sets the torque reference delay time

in ms units.
;

This function can be used to ad-

just the noise of the torque con-

trol signal or the responsiveness

0 to

1000

0

x

x

x

x

A

7 - 24

d5 02

Torq Ref Filter

j

q

trol signal or the responsiveness

with the host controller. When

oscillation occurs during torque

control, increase the set value.

1000

0

x

x

x

x

A

7 - 24

d5-03

Speed limit selection

Sets the speed limit command

method for the torque control

mode.
1: The analog input limit from an

1 2

1

x

x

x

x

A

7 21

d5-03

Speed Limit Sel

1: The analog input limit from an

analog frequency reference ter-

minal (terminals 13 and 14.)

2: Limited by d5-04 constant set-

ting values.

1, 2

1

x

x

x

x

A

7 - 21

d5-04

Speed limit

Sets the speed limit during torque

control as a percentage of the maxi-

mum output frequency.
;

This function is enabled when

d5 03 is set to 2 Directions are

--120 to

0

x

x

x

x

A

7 21

d5-04

Speed Lmt Value

;

d5-03 is set to 2. Directions are

as follows.

+: operation command direction

--: operation command opposite

direction

--120 to

+120

0

x

x

x

x

A

7 - 21

d5-05

Speed limit bias

Sets the speed limit bias as a per-

centage of the maximum output fre-

quency.
;

Bi i i

t th

ifi d

0 to 120

10

x

x

x

x

A

7 23

d5-05

Speed Lmt Bias

;

Bias is given to the specified

speed limit. It can be used to ad-

just the margin for the speed lim-

it.

0 to 120

10

x

x

x

x

A

7 - 23

d5-06

Speed/torque control

switching timer

Sets the delay time from inputting

the multi-function input “speed/

torque control change” (from ON to

OFF or OFF to ON) until the con-

trol is actually changed, in ms units.
;

This function is enabled when

the multi-function input “speed/

torque control change” is set. In

0 to

1000

0

x

x

x

x

A

7 - 26

d5 06

Ref Hold Time

torque control change is set. In

the speed/torque control switch-

ing timer, the three analog inputs

hold the values of when the

“speed/torque control change”

changes. Always be sure to allow

time for this process to finish

completely.

1000

0

x

x

x

x

A

7 - 26