Advanced Operation

7.5.1 Application Constants: b

7 - 42

J

Speed Search: b3-01 to b3-03

The speed search function finds the speed of a coasting motor and starts up smoothly from that speed. It is

effective in situations such as switching from a commercial power supply.

Speed Search Selection at Start: b3-01

User

Change

during

Setting

Factory

Valid Access Levels

User

Constant

Number

Name

g

during

Opera-

tion

Setting

Range

Unit Factory

Setting

V/f

Control

V/f with

PG

Open

Loop

Vector

Flux

Vector

b3-01

Speed search selection

at start

x

0, 1

--

0 *

A

A

A

A

* When the control method is switched, the factory setting changes as follows:

V/f control: 0; V/f with PG: 1; open-loop vector 0; flux vector: 1

D

Settings

Setting

Contents

0

Speed search disabled:

Motor starts from minimum output frequency.

1

Speed search enabled:

Speed search is performed from maximum output frequency and motor

is started. (In control methods with PG, i.e., V/f with PG feedback and

flux vector, motor starts from the motor speed.)

D

Set “1” to use the speed search function. A speed search is performed each time the run command is

input.

D

To use speed search freely in control methods without PG, i.e., V/f control and open-loop vector control,

set the multi-function contact input selection (H1-01 to H1-06) to 61 or 62 (external search command).

(See para 7.5.5.)

Speed Search Operating Current, Speed Search Deceleration Time, and Min. Baseblock Time:

b3-02, b3-03, L2-03

User

Change

during

Setting

Factory

Valid Access Levels

User

Constant

Number

Name

g

during

Opera-

tion

Setting

Range

Unit Factory

Setting

V/f

Control

V/f with

PG

Open

Loop

Vector

Flux

Vector

b3-02

Speed search operat-

ing current

x

0 to 200

%

100

(150)

*1

A

x

A

x

b3-03

Speed search decel-

eration time

x

0.1 to 10.0

s

2.0

A

x

A

x

L2-03

Min. baseblock time

x

0.0 to 0.5

s

0.5

*2

B

B

B

B

* 1. The factory setting for V/f control is 150%.
* 2. The factory setting varies depending on the Inverter capacity. The values shown in the table

are for 400-V class Inverters of 200 kW.

D

For the speed search operating current (b3-02), set the operating current for the speed search. If restart-

ing is not possible with the setting, then lower the setting.

D

Set the speed search operating current as a percentage of the Inverter’s rated output current, with the

Inverter’s rated output current taken as 100%.

D

For the speed search deceleration time (b3-03), set the output frequency deceleration time for while the

speed search is being performed. Set the time required to decelerate from the maximum output frequen-

cy to 0 Hz.

D

When the speed search and DC injection braking are set, set the minimum baseblock time (L2-03). For

the minimum baseblock time, set the time to wait for the motor’s residual voltage to dissipate. If an over-

current is detected when starting a speed search or DC injection braking, raise the setting to prevent a

fault from occurring.