background image

4.2 Modes

4 - 31

Group

Control

Method

Comments

Display

Function

Group

Fl

ux

Ve

ct

or

Open

-loop

Vector

V/

fw

/P

G

V/

f

Comments

Display

Function

F1

PG speed control card

settings

PG Option Setup

User constant settings for a PG Card

X f X f

F2

Analog Reference Card

AI

AI-14 Setup

User constant settings for an Analog Ref-

erence Card

f f f f

F3

Digital Reference Card DI DI-08, 16 Setup

User constant settings for a Digital Refer-

ence Card

f f f f

F4

Analog Monitor Card AO

AO-08, 12 Setup

User constant settings for an Analog

Monitor Card

f f f f

F Options

F5

Digital Output Card DO

DO-02C

User constant settings for a Digital Out-

put Card

f f f f

F6

Digital Output Card DO

DO-08

User constant settings for a Digital Out-

put Card

f f f f

F7

Pulse Monitor Card PO

PO-36F Setup

User constant settings for a Pulse Monitor

Card

f f f f

F8

SI-F/SI-G Transmission

Card

SI-F/G

User constant settings for a Transmission

Card

f f f f

F9

CP-916B Transmission

Card

DDS/SI-B

User constant settings for a Transmission

Card

f f f f

H1

Multi-function inputs

Digital Inputs

Function selection for multi-function in-

puts

f f f f

H2

Multi-function outputs

Digital Outputs

Function selection for multi-function out-

puts

f f f f

H Terminal

H3

Analog inputs

Analog Inputs

Function selection for analog inputs

f f f f

H4

Multi-function analog out-

puts

Analog Outputs

Function selection for analog outputs

f f f f

H5

MEMOBUS communica-

tions

Serial Com Setup

MEMOBUS communications settings

f f f f

L1

Motor protection functions Motor Overload

Overload protection settings and selection f f f f

L2

Momentary power loss

ride-through

PwrLoss Ridethru

Selects the power-loss processing meth-

od.

f f f f

L3

Stall prevention

Stall Prevention

Stall prevention settings and selection

f f f f

L Protection

L4

Frequency detection

Ref Detection

Frequency detection settings and selec-

tion

f f f f

L Protection

L5

Fault restart

Fault Restart

Fault restart function settings

f f f f

L6

Overtorque detection

Torque Detection

Overtorque detection settings and selec-

tion

f f f f

L7

Torque limits

Torque Limit

Torque limit settings (vector control only) X X f f

L8

Hardware protection

Hdwe Protection

Overheating and phase loss protection

settings

f f f f

o1

Display/Monitor settings

Monitor Select

Selects the display and setting methods.

f f f f

o Operator

o2

Function settings

Key Selections

Key function selection and other user

constants

f f f f

Figure 4.11 shows the difference in the display structure for the various access levels.