5 dismounting and mounting the module, Warning – Yaskawa G5HHP Drive User Manual

Page 330

Advertising
background image

Maintenance and Inspection

10.1.5 Dismounting and Mounting the Module

10 - 6

10.1.5 Dismounting and Mounting the Module

WARNING

D

Before mounting or dismounting a Module, make sure that the main circuit and control power sup-

ply have been turned OFF.

Not doing so can result in electric shock.

D

Do not dismount a Module until the CHARGE lamp on the Module turns OFF after turning OFF the

power supply.

An electric shock may occur is the Module is dismounted while still charged.

D

Use special lifts for mounting or dismounting the Module.

Not doing so can result in injury.

D

The Modules are heavy, and mounting or dismounting the Modules must be performed by three

workers: One to operate the lift and two others for mounting and dismounting the Modules.

Not doing so can result in injury

Refer to Figure 10.5.

Inverter Module

Power Supply Unit

Control Unit

CHARGE lamp

Refer to Figure 10.7.

Refer to Figure 10.10.

Refer to Figure 10.6.

Refer to Figures 10.11 and 10.13.

Refer to Figure 10.8.

Refer to Figures 10.9

and 10.12.

Refer to Figure 10.12.

Fig 10.4

Inverter Panel

10

Advertising