Appendix – Yaskawa G5HHP Drive User Manual

Page 364

Advertising
background image

Appendix

12 - 16

F2-01

Bi-polar or uni-polar input selection

(AI-14 Input Sel)

0

H3-09

Multi-function analog input (terminal 39)

(Terminal 39 Sel)

1F

F3-01

Digital input option

(DI Input)

0

H3-10

Gain (terminal 39)

(Terminal 39 Gain)

100.0

F4-01

Channel 1 monitor selection

(AO Ch1 Select)

2

H3-11

Bias (terminal 39)

(Terminal 39 Bias)

0.0

F4-02

Channel I gain

(AO Ch1 Gain)

1.00

H3-12

Analog input filter time constant

(Filter Avg Time)

0.00

* 1. Not displayed for some models depending on software version No.
* 2. These are values for a 400-V class Inverter. Multiply the value by approx. 1.5 for a 575-V class Inverter.
* 3. Setting unit and initial setting depend on Inverter capacity.
* 4. Depends on the control method (A1-02).
* 5. Factory setting in the parentheses is for 3-wire sequence.

12