Speed search: b3, Timer function: b4, Pid control: b5 – Yaskawa G5HHP Drive User Manual

Page 272

Advertising
background image

User Constants

8.2.1 Application Constants: b

8 - 6

J

Speed Search: b3

C

t t

Name

S tti

F t

Change

Control Methods

Constant

Number

Display

Description

Setting

Range

Factory

Setting

Change

during

Opera-

tion

V/f

V/f

with

PG

Open

Loop

Vector

Flux

Vector

Page

b3-01

Speed search selec-

tion at start

Sets the speed search function to

start when the run command is in-

put.
0: Disabled (Starts from the mini-

mum output frequency.)

1: Enabled (Speed search is started

0, 1

0 *

x

A

A

A

A

7 - 42

b3 01

SpdSrch at Start

1: Enabled (Speed search is started

from the maximum frequency.

In a control method with PG,

the motor starts at the frequency

of motor rotation when the run

command is input.)

0, 1

0

x

A

A

A

A

7 - 42

b3-02

Speed search operat-

ing current

Sets the speed search operation cur-

rent as a percentage of the Inverter

rated current.
;

Not usually necessary to set.

0 to 200

100

x

A

x

A

x

7 - 42

b3 02

SpdSrch Current

;

Not usually necessary to set.

When restarting is not possible

with the set value, reduce the

value.

0 to 200

100

x

A

x

A

x

7 - 42

b3-03

Speed search decel-

eration time

Sets the output frequency decelera-

tion time during speed search in

1-second units.
;

Set the time for deceleration

0.1 to

10 0

2.0

x

A

x

A

x

7 - 42

b3 03

SpdSrch Dec Time

;

Set the time for deceleration

from the maximum output fre-

quency to 0 Hz.

10.0

2.0

x

A

x

A

x

7 - 42

* When the control method is changed, the Inverter reverts to factory settings. (The open loop vector control factory settings will

be displayed.)

J

Timer Function: b4

C

t t

Name

S tti

F t

Change

Control Methods

Constant

Number

Display

Description

Setting

Range

Factory

Setting

Change

during

Opera-

tion

V/f

V/f

with

PG

Open

Loop

Vector

Flux

Vector

Page

b4-01

Timer function ON-

delay time

Sets the timer function output ON-

delay time (dead band) for the timer

function input, in 1-second units.
;

Enabled when the timer function

0.0 to

300 0

0.0

x

A

A

A

A

7 - 43

b4 01

Delay-ON Timer

;

Enabled when the timer function

is set for multi-function inputs

and outputs.

300.0

0.0

x

A

A

A

A

7 - 43

b4-02

Timer function OFF-

delay time

Sets the timer function output OFF-

delay time (dead band) for the timer

function input, in 1-second units.
;

E bl d h

th ti

f

ti

0.0 to

300 0

0.0

x

A

A

A

A

7 - 43

b4 02

Delay-OFF Timer

;

Enabled when the timer function

is set for multi-function inputs

and outputs.

300.0

0.0

x

A

A

A

A

7 - 43

J

PID Control: b5

C

t t

Name

S tti

F t

Change

Control Methods

Constant

Number

Display

Description

Setting

Range

Factory

Setting

Change

during

Opera-

tion

V/f

V/f

with

PG

Open

Loop

Vector

Flux

Vector

Page

b5-01

PID control mode

selection

0: Disabled
1: Enabled (Deviation is D-con-

trolled.)

0 to 2

0

f

A

A

A

A

7 - 46

b5 01

PID Mode

trolled.)

2: Enabled (Feedback value is D-

controlled.)

0 to 2

0

f

A

A

A

A

7 - 46

8