Wiring

3 - 4

IM

U/T1

FM

Analog output

monitor

Frequency meter

+

Forward run command

(forward when closed)

9

Forward Run/Stop

V/T2

T/L3

S/L2

R/L1

W/T3

+

--

Reverse run command

(reverse when closed)

10

(External fault)

11

(Fault reset)

12

(Master/auxiliary speed)

13

(Multi-step speed 2)

14

(External baseblock

reference)

15

Sequence common

(Insulated from 0 V

terminal)

38

36

Master speed frequency ref-

erence

(--10 to +10V/0 to 10V)

39

42

Speed reference

common

35

0V

MCCB

Speed setting adjust-

ment resistor (2 kΩ)

Speed setting

resistor (2 kΩ)

Fault contact output

250 VAC, 1 A max.

30 VDC, 1 A max.

Operation output

250 VAC, 1 A max.

30 VDC, 1 A max.

45

0V

48

25

52

23

57

19

20

50

1

17

Shield terminal

2TB

1TB

1TB

Frequency reference

46

Braking Unit

(Optional)

T1/L31

S1/L21

R1/L11

*Power transformer for

12-phase rectification

PG

AM

+

Output am-

meter

PG

4CN

2CN

3CN

Ventilation fan fault detection

F1

F2

+15 V power for analog

reference

--15 V power for analog refer-

ence

44

Multi-function

analog input

16

(Jog reference)

34

Frequency reference

53

200-VAC input terminals for

ventilation fan

Control power input

terminals

200/

r/

2

400/

1

575 V:

400

2

r200

200

200

575/

575

2

(Not for 575 V)

VS--616G5

Motor

Braking Resistor Unit (Optional)

(Optional)

(Optional)

(Optional)

Monitor

Open collector 1

Multi-function output common

Multi-function

open-collector output

48 VDC, 50 mA max.

Multi-function analog input
(--10 to +10 V/0 to 10 V)

Master speed frequency
reference (4 to 20 mA)

Reference

When using the 12-phase

rectification input, remove the input

terminal short-circuit bus bar.

Reverse Run/Stop
Multi-function contact

input 1
Multi-function contact

input 2
Multi-function contact

input 3
Multi-function contact

input 4
Multi-function contact

input 5
Multi-function contact

input 6

Note

(1) Double circles indicate main circuit terminals and single circles indicate control circuit terminals.

(2) When using the 12-phase rectification, the user must prepare the transformer.

Open collector 2

2TB

Fig 3.1

Connection Diagram (Model CIMR-G5A4200 Shown Above)