User Constants

8.2.3 Reference Constants: d

8 - 16

8.2.3 Reference Constants: d

J

Preset Reference: d1

C

t t

Name

S tti

F t

Change

Control Methods

Constant

Number

Display

Description

Setting

Range

Factory

Setting

Change

during

Opera-

tion

V/f

V/f

with

PG

Open

Loop

Vector

Flux

Vector

Page

d1-01

Frequency reference

1

Sets the frequency reference in the

units used in o1-03 (frequency ref-

erence display/set units ) The facto-

0.00

f

Q

Q

Q

Q

6 - 7

d1 01

Reference 1

erence display/set units.) The facto-

ry setting unit for o1-03 is Hz.

0.00

f

Q

Q

Q

Q

6 - 7

d1-02

Frequency reference

2

The frequency reference when the

multi-function input “multi-step

0.00

f

Q

Q

Q

Q

6 - 7

d1 02

Reference 2

multi function input multi step

speed reference 1” is ON.

0.00

f

Q

Q

Q

Q

6 - 7

d1-03

Frequency reference

3

The frequency reference when the

multi-function input “multi-step

0.00

f

Q

Q

Q

Q

6 - 7

d1 03

Reference 3

multi function input multi step

speed reference 2” is ON.

0.00

f

Q

Q

Q

Q

6 - 7

d1-04

Frequency reference

4

The frequency reference when the

multi-function input “multi-step

0.00

f

Q

Q

Q

Q

6 - 8

d1 04

Reference 4

multi function input multi step

speed reference 1, 2” is ON.

0.00

f

Q

Q

Q

Q

6 - 8

d1-05

Frequency reference

5

The frequency reference when the

multi-function input “multi-step

0 to

150 00

0.00

f

B

B

B

B

6 - 8

d1 05

Reference 5

multi function input multi step

speed reference 3” is ON.

0 to

150.00

0.00

f

B

B

B

B

6 - 8

d1-06

Frequency reference

6

The frequency reference when the

multi-function input “multi-step

0.00

f

B

B

B

B

6 - 8

d1 06

Reference 6

multi function input multi step

speed reference 1, 3” is ON.

0.00

f

B

B

B

B

6 - 8

d1-07

Frequency reference

7

The frequency reference when the

multi-function input “multi-step

0.00

f

B

B

B

B

6 - 8

d1 07

Reference 7

multi function input multi step

speed reference 2, 3” is ON.

0.00

f

B

B

B

B

6 - 8

d1-08

Frequency reference

8

The frequency reference when the

multi-function input “multi-step

0.00

f

B

B

B

B

6 - 8

d1 08

Reference 8

multi function input multi step

speed reference 1, 2, 3” is ON.

0.00

f

B

B

B

B

6 - 8

d1-09

Jog frequency refer-

ence

The frequency reference when the

multi-function inputs, “Jog frequen-

cy reference selection,” “FJOG

6.00

f

Q

Q

Q

Q

6 - 8

d1 09

Jog Reference

cy reference selection, FJOG

command,” and “RJOG command”

are ON.

6.00

f

Q

Q

Q

Q

6 - 8

J

Reference Limits: d2

C

t t

Name

S tti

F t

Change

Control Methods

Constant

Number

Display

Description

Setting

Range

Factory

Setting

Change

during

Opera-

tion

V/f

V/f

with

PG

Open

Loop

Vector

Flux

Vector

Page

d2-01

Frequency reference

upper limit

Sets the output frequency upper

limit as a percentage of the maxi-

0.0 to

110 0

100.0

x

B

B

B

B

7 - 54

d2 01

Ref Upper Limit

limit as a percentage of the maxi

mum output frequency.

110.0

100.0

x

B

B

B

B

7 - 54

d2-02

Frequency reference

lower limit

Sets the output frequency lower

limit as a percentage of the maxi-

0.0 to

109 0

0.0

x

B

B

B

B

7 - 54

d2 02

Ref Lower Limit

limit as a percentage of the maxi

mum output frequency.

109.0

0.0

x

B

B

B

B

7 - 54