Yaskawa G5HHP Drive User Manual

Page 361

Advertising
background image

12.7 User Constants

12 - 13

* 1. Not initialized. (Japanese standard specifications: A1-01 = 1, A1-02 = 2)
* 2. Not displayed for some models depending on software version No.
* 3. Factory setting depends on the control method (A1-02).

Table 12.1 User Constants (Continued)

No.

Name

(Display)

Factory

Setting

Setting

No.

Name

(Display)

Factory

Setting

Setting

C4-02

Torque compensation time constant

(Torq Comp Time)

20

*

1

d3-04

Jump frequency width

(Jump Bandwidth)

1.0

C5-01

ASR proportional (P) gain 1

(ASR P Gain 1)

20.00

*

1

d4-01

Frequency reference hold function selection

(MOP Ref Memory)

0

C5-02

ASR integral (I) time 1

(ASR I Time 1)

0.500

*

1

d4-02

+ -- Speed limits

2

(Trim Control Lvl)

25

C5-03

ASR proportional (P) gain 2

(ASR P Gain 2)

20.00

*

1

d5-01

Torque control selection

(Torq Control Sel)

0

C5-04

ASR integral (I) time 2

(ASR I Time 2)

0.500

*

1

d5-02

Torque reference delay time

(Torq Ref Filter)

0

C5-05

ASR limit

(ASR Limit)

5.0

d5-03

Speed limit selection

(Speed Limit Sel)

1

C5-06

ASR primary delay time

(ASR Delay Time)

0.004

d5-04

Speed limit

(Speed Lmt Value)

0

C5-07

ASR switching frequency

(ASR Gain SW Freq)

0.0

d5-05

Speed limit bias

(Speed Lmt Bias)

10

C5-08

ASR integral (I) limit

2

(ASR I Limit)

400

d5-06

Speed/torque control switching timer

(Ref Hold Time)

0

C6-01

Carrier frequency upper limit

(Carrier Freq Max)

2.0

*

3

E1-01

Input voltage setting

(Input Voltage)

400

*

4

C6-02

Carrier frequency lower limit

(Carrier Freq Min)

2.0

*

3

E1-02

Motor selection

(Motor Selection)

0

C6-03

Carrier frequency proportional gain

(Carrier Freq Gain)

0

*

3

E1-03

V/f pattern selection

(V/F Selection)

0F

C7-01

Hunting prevention selection

(Hunt Prev Select)

1

E1-04

Max. output frequency

(Max Frequency)

60.0

C7-02

Hunting prevention gain

(Hunt Prev Gain)

1.00

E1-05

Max. voltage

(Max Voltage)

400.0

*

4

C8-08

AFR gain

(AFR Gain)

1.00

E1-06

Base frequency

(Base Frequency)

60.0

C8-09

Speed feedback detection control (AFR) time*

2

(AFR Time)

50

E1-07

Mid. output frequency

(Mid. Frequency A)

3.0

*

1

C8-30

Carrier frequency during autotuning

2

(Carrier in tune)

2

E1-08

Mid. output frequency voltage

(Mid Voltage A)

22.0

*

1

*

4

d1-01

Frequency reference 1

(Reference 1)

0.00

E1-09

Min. output frequency

(Min Frequency)

0.5

*

1

d1-02

Frequency reference 2

(Reference 2)

0.00

E1-10

Min. output frequency voltage

(Min Voltage)

4.0

*

1

*

4

d1-03

Frequency reference 3

(Reference 3)

0.00

E1-11

Mid. output frequency 2

*

2

(Mid Frequency B)

0.0

d1-04

Frequency reference 4

(Reference 4)

0.00

E1-12

Mid. output frequency voltage 2

*

2

Mid Voltage B)

0.0

d1-05

Frequency reference 5

(Reference 5)

0.00

E1-13

Base voltage

2

(Base Voltage)

0.0

d1-06

Frequency reference 6

(Reference 6)

0.00

E2-01

Motor rated current

(Motor Rated FLA)

370.0

*

3

d1-07

Frequency reference 7

(Reference 7)

0.00

E2-02

Motor rated slip

(Motor Rated Slip)

1.30

*

3

d1-08

Frequency reference 8

(Reference 8)

0.00

E2-03

Motor no-load current

(No-Load Current)

96.0

*

3

d1-09

Jog frequency reference

(Jog Reference)

6.00

E2-04

Number of motor poles

(Number of Poles)

4

d2-01

Frequency reference upper limit

(Ref Upper Limit)

100.0

E2-05

Motor line-to-line resistance

(Term Resistance)

0.020

*

3

d2-02

Frequency reference lower limit

(Ref Lower Limit)

0.0

E2-06

Motor leak inductance

(Lead Inductance)

5.0

*

3

d3-01

Jump frequency 1

(Jump Freq 1)

0.0

E2-07

Motor iron-core saturation coefficient 1

(Saturation Comp 1)

0.50

12

Advertising