Advanced Operation

7.5.2 Tuning Constants: C

7 - 52

Slip Compensation Selection During Regeneration: C3-04

User

Change

during

Setting

Factory

Valid Access Levels

User

Constant

Number

Name

g

during

Opera-

tion

Setting

Range

Unit Factory

Setting

V/f

Control

V/f with

PG

Open

Loop

Vector

Flux

Vector

C3-04

Slip compensation

selection during re-

generation

x

0, 1

--

0

A

A

A

x

D

Settings

Setting

Contents

0

Slip compensation disabled during regeneration

1

Slip compensation enabled during regeneration

D

Constant C3-04 enables or disables slip compensation during regeneration.

D

The amount of regeneration is momentarily increased when this function is used, so some control option

(e.g., Braking resistor, Braking Resistor Unit, Braking Unit) may be required.

J

Torque Compensation Function: C4-01, C4-02

The torque compensation function detects increases in the motor load, and increases the output torque to

compensate.

Torque Compensation Gain: C4-01

User

Change

during

Setting

Factory

Valid Access Levels

User

Constant

Number

Name

g

during

Opera-

tion

Setting

Range

Unit Factory

Setting

V/f

Control

V/f with

PG

Open

Loop

Vector

Flux

Vector

C4-01

Torque compensation

gain

x

0.00 to 2.50 Mul-

tiple

1.00

B

B

B

x

D

This constant can be changed during operation, but normally no adjustments are required. Make adjust-

ments in the following cases under the V/f control mode:

If the wiring distance between the Inverter and the motor is long, raise the setting.

If the motor capacity is less than the Inverter capacity (the maximum application motor capacity),

raise the setting.

If the motor generates excessive oscillation, lower the setting.

D

Set the torque compensation gain so that the output current at low-speed rotation does not exceed 50%

of the Inverter’s rated output current.

D

Do not adjust the setting of this constant for open-loop vector control.

Torque Compensation Time Constant: C4-02

User

Change

during

Setting

Factory

Valid Access Levels

User

Constant

Number

Name

g

during

Opera-

tion

Setting

Range

Unit Factory

Setting

V/f

Control

V/f with

PG

Open

Loop

Vector

Flux

Vector

C4-02

Torque compensation

time constant

x

0 to 10000

ms

20 *

A

A

A

x

* When the control method is switched, the factory setting changes as follows:

V/f control: 200; V/f with PG: 200; open-loop vector: 20

D

The torque compensation time constant does not normally need to be adjusted, but make adjustments

in the following cases:

If the motor generates excessive oscillation, raise the setting.

If motor responsiveness is low, lower the setting.