11.2 Specifications of Options and Peripheral Devices

11 - 7

Table

11.2

Optional Cards (Continued)

Type

Name

Code No.

Descriptions

Manual No.

r)

PG-A2

73600-A012X

Used for V/f control. Speed feedback is performed using the PG

attached to the motor to compensate for speed fluctuations caused

by slipping.

S

A-phase pulse (single pulse) input (voltage, complementary, open-

collector input)

S

Maximum input frequency: 32767 Hz

S

Pulse monitor output: +12 V, 20 mA

(PG power supply output: +12 V, 200 mA max.)

TOE-C736-40.1

nec

tt

o

connec

to

r)

C

ont

rol

C

ards

PG-B2

73600-A013X

S

Used for flux vector control.

S

A-, B-phase input (complimentary input)

S

Maximum input frequency: 32767 Hz

S

Pulse monitor output: Open-collector

(PG power supply output: +12 V, 200 mA max.)

TOE-C736-40.2

Bu

ilt-

in

(c

on

ne

P

G

S

peed

C

o

PG-D2

73600-A014X

S

Differential input.

S

A-phase pulse (differential pulse) input, for V/f control

S

Maximum input frequency: 300 kHz

S

Input: Conforms to RS-422

S

Pulse monitor output: RS-422

(PG power supply output: +5 or +12 V, 200 mA max.)

TOE-C736-40.3

PG-X2

73600-A015X

Used for flux vector control.

S

A-, B-, Z-phase pulse (differential pulse) input

S

Maximum input frequency: 300 kHz

S

Input: Conforms to RS-422

S

Pulse monitor output: RS-422

(PG power supply output: +5 or +12 V, 200 mA max.)

TOE-C736-40.4

Synchronous Phase Control

Card

SP-A2

73600-A016X

Connector to Inverter to enable synchronized startup control with

the motor. An external voltage detection transformer (CPT005845)

is required

TOE-C736-40.5