Maintenance and Inspection
10.1.5 Dismounting and Mounting the Module
10 - 14
J
Disposing of the Module
WARNING
D
Before disposing of the Module, open a hole in the heat sink attached to the Module to purge gas.
Exposing the heat sink to a high temperature without opening a hole in the heat sink can result in explosion
and injury.
Before disposing of the Module, cut the refrigerant charging port and open a hole in the heat sink.
Heat Sink
Module
Fig 10.16 Heat Sink