Dme effects for keys – Sony GP-X1EM Grip Extension User Manual

Page 122

Advertising
background image

122

When selecting [Angle] in the <Rotation> group
and slanting the pattern

a) See

page 148

.

When selecting [Speed] in the <Rotation> group
and rotating the pattern at a constant speed

a) See

page 148

.

Using the sub mask

1

Open the M/E-1 >Key1 >Sub Mask menu (1114).

2

In the <Mask Type> group, select the mask type.

Key Mask:

Masks a part of a key.

Bkgd Mask:

Masks a part of a background.

3

In the <Mask Source> group, select the mask source.

Wipe:

Wipe pattern selected for a transition.

Press [Pattern Select] to open the M/E-1 >Wipe
>Main Pattern menu (1151), and select a pattern
and set modifiers

(see page 142)

.

In patterns selected for a mask, modifiers for wipe
direction and edges are disabled.

Utility 1 Bus:

Signal selected on the utility 1 bus.

On the cross-point control block, press delegation
button [UTL1] on the cross-point pad and select a
signal using the cross-point buttons.

• On the cross-point control block in key/AUX bus

delegation mode, press the [UTIL1] button in the 1st
row and select a signal using the cross-point buttons
in the 2nd row.

• You can assign the utility 1 bus using the [UTIL]

button on the cross-point pad of the cross-point
control block

(see page 80)

.

• You can assign a utility 1 bus delegation button to

the 1st row or 2nd row of the AUX bus control block
(AUX bus operation mode) in the Setup menu

(see

page 419)

.

4

Depending on the selection in step

3

, set the following

parameters.

When [Wipe] is selected

When [Utility 1 Bus] is selected

5

To invert the mask source, press [Mask Invert],
turning it on.

DME Effects for Keys

DME restrictions

• When the switcher signal format is 3840×2160P SQD or

3840×2160PsF SQD, the DME function cannot be used.

• There are restrictions on the number of DME channels

that can be used and on the functions, depending on the
switcher and signal format.

For differences in functions by switcher, see “XVS-9000/
8000/7000/6000 System Configuration Comparison”
(page 526).
For details about restrictions for 4K format, see “4K
Format Restrictions” (page 528)
.

• The number of keys to which DME effects (including

DME wipes) can be applied simultaneously for one M/E
bank varies as follows depending on the execution mode
of the DME wipe pattern selected for the background.

When the signal format is 3840×2160P 2SI, DME
effects (including DME wipes) can be used
simultaneously in only one place on an M/E bank. When
not using background DME wipes, DME effects can be
used on either key 1 or key 2.

• If an image effect is set, the number of keys that can

simultaneously use a DME on an M/E bank is restricted

(see page 197)

.

• You cannot use DME effects on a key for which the

resizer function is enabled. Disable the resizer using the
M/E-1 >Key1 >Resizer menu (1115).

No.

Parameter

Adjustment

1

Angle

Rotation angle of pattern

a)

No.

Parameter

Adjustment

1

Speed

Rotation speed of pattern

a)

Note

Notes

No.

Parameter

Adjustment

1

Size

Pattern size

2

Soft

Edge softness

No.

Parameter

Adjustment

1

Clip

Reference level for creating mask
signal

2

Gain

Gain

Key to which
DME effects are
applied

DME wipe pattern
for background

Number of keys
to which DME
effects can be
applied
simultaneously

Keys 1 to 4

DME wipes not
used

2

1-channel mode

1

2-channel or
3-channel mode

0

Keys 5 to 8

2

Advertising