Sony GP-X1EM Grip Extension User Manual

Page 478

Advertising
background image

478

4

Select the action to set.

a) For “Aux ? O’ride Src ??” action
b) For “Prefs Button ?” action

5

Press [Action Set].

Trigger type and actions list

1)

• When the trigger type is other than “Level”

M/E-x Cut, M/E-x Auto Trans, P/P Cut, P/P Auto Trans,
M/E-x Keyx Cut, M/E-x Keyx Auto Trans, P/P Keyx
Cut, P/P Keyx Auto Trans, FTB Auto Trans, FTB Cut,
Master SS ? Recall, SS ? Recall, M/E-x Keyx SS ?
Recall, P/P Keyx SS ? Recall, Master Effect ? Recall,
Effect ? Recall, Effect ? Recall & Run, KF Run, KF
Stop, KF Rewind, Shotbox ? Recall, Macro Take, Macro
? Recall, Prefs Button ?, No Action
Aux ? O’ride Src ??

2)

• When the trigger type is “Level”

System Format, System Aspect, Level Enable, Panel
Status, No Action

1) M/E-x: where x is the M/E number (1 to 5)

Keyx: where x is the key number (1 to 8)

2) When the trigger type is only “Rising Edge” or “Falling Edge”

• “Level Enable” is a function that determines whether GPI

inputs are enabled (“Enable”) or disabled (“Disable”) for the
“System Aspect” and “System Format” actions that can be
used when the trigger type is “Level.” If the input is disabled
(“Disable”) when “Level Enable” is selected, “System Aspect”
and “System Format” cannot be switched by the GPI input.
If a GPI action is triggered just as system power is turned off,
such as by switching “System Aspect” or “System Format,” the
action may be executed immediately before the power goes off
and the power may go off before the action is completed. This
may corrupt the setup. It is therefore recommended to use
“Level Enable” to avoid such a situation.

• “Aux ? O’ride Src ??” switches the AUX bus input. For

example, when “Rising Edge” is selected, the configured
AUX bus input is used on the rising edge and then
returns to the original cross-point on the falling edge. If
the GPI trigger is applied repeatedly at short intervals
(0.5 seconds or less), the cross-point switching may not
be carried out correctly. In this case, apply the GPI
trigger again.

• In Dual Simul mode, you can select the target switcher

for the panel status display using “Panel Status”
(H=SWR1, L=SWR2).

Configuring level settings

Configure the settings for low level and high level when
the trigger type is set to “Level.”

1

In the Engineering Setup >DCU >GPI Input Assign
menu (7352), select an action and press [H/L Set].

The H/L Set menu (7352.1) appears.

2

Select the setting.

3

To trigger an action when the input is high level or low
level, press [H Set] or [L Set], respectively.

If the action is “System Format,” press [H Set] or [L
Set] in the <System> group.

No.

Parameter

Adjustment

2

Action

Action selection

4

a)

Aux Bus
No

AUX bus selection

5

Reg No

Register number

5

a)

Src No

Source signal selection

5

b)

No

Button number

Notes

No.

Parameter

Adjustment

2

Item No

Selection of setting for action

Advertising